The most important points
in brief
1 ON/OFF button
2 LED indicator “appliance ON”
3 Room thermostat
(electric operation)
4 LED indicator “appliance heating up“
5 LED indicator “rapid heating function”
6 Short-time timer for “rapid heating
function”
7 ON/OFF button for “rapid heating
function”
S1 ON/OFF switch for immersion
heater
V1 LED indicator light “immersion
heater operating”

 

V1
S1
652
71
4
3
C26_07_80_0003
C26_07_80_0014
10
1. Operating instructions for users and contractors
The installation and use of electrical appliances
must be carried out with due caution in order
to avoid the risk of fire, electric shock or injury.
The equipment must only be used as described
in these instructions. Any use outside of the
manufacturer recommendations could lead to
damage, fire, shock or injury.
The heat requirement of the room should be
matched to the heat output of the unit.
Before using the appliance the instructions
should be read in their entirety and all ap-
propriate handling of the equipment must be
observed.
These instructions should be kept safe-
ly and passed on to any future owner.
In the event of any repair work, hand them
WRWKHTXDOLÀHGLQVWDOOHUIRUKLVDWWHQWLRQ
1.1 Unit description
The BHC thermofan duo towel rail radiator is
suitable for use as full or supplementary heat-
ing as well as for drying and warming towels.
There are several levels for hanging these.
The units can be operated either as electric
room heaters or as heating elements within a
hot water central heating system.
During operation, the room air over the
surface of the heating element is heated and
distributed through the room by natural con-
vection.
The unit also has a time-limited electric
rapid heater (1000 W) with fan that can be
switched on when required.
The electrical connection is by means of mains
plug.
Operation with a hot water central
heating system
Even when the central heating is switched
off, the heating element can be heated via
the integral electric Direct immersion heater
(750 W) fitted as standard (see 1.3.2 Summer
operation).
Do not operate the immersion heater
unless the radiator is full; otherwise
the radiator will be damaged.
1.2 Operation as an electric
room heater
The BHC is fully controlled via the control
panel on the front after the Direct immersion
heater has been switched on using switch S1.
The heater is be switched on via the ON/OFF
button (1). Set the room temperature to
between approx. + 6 °C and + 30 °C on the
room thermostat (3).
After the adjusted ambient temperature has
been reached, it will remain constantly, until the
appliance is switched off (the heating capacity
of the appliance must correspond at least to
the necessary heat requirement of the room).
Rapid heating function
With the rapid-heating-function the imersion
heater (if switch on) and the rapid-heater
(A2) will run for the preselected period for
continuous operation, regardless of the tem-
perature set on the room thermostat.
The heating time can be set at ¼ h, ½ h, 1 h
or 2 h on the short-time timer (6) and is acti-
vated by the rapid-heating button (7).
If the heating time is to be ended before the
end of the set period, the rapid heating button
must be pressed again.
Frost protection
In the event of a lengthy absence, the room
temperature should not fall below approx.
+6 °C (frost protection) and the room ther-
mostat should be turned to the  position
and the appliance must remain switched on
(observe the heating capacity of the appliance
and heat requirement of the room).
1.3 Operation in a central
heating system
1.3.1 Winter operation
The central hot-water heating system is op-
erating.
The temperature of the BHC is controlled by
means of the thermostatic valve installed site
wise.
The electrical rapid heater can be switched on
via the control panel.
Rapid heating function
Switch on the ON/OFF button (1).
In addition, the rapid heating function can be
used to switch on the rapid heater (A2) for a
pre-selected period.
The heating time can be set at ¼ h, ½ h, 1 h
or 2 h on the short-time timer (6) and is acti-
vated by the rapid-heating button (7).
If the heating time is to be ended before the
end of the set period, the rapid heating button
must be pressed again.
Frost protection
In the event of a lengthy absence, the room
temperature should not fall below approx.
+6 °C (frost protection) and the thermostatic
valve should be turned to the  position
(observe the heating capacity of the appliance
and heat requirement of the room).
1.3.2 Summer operation
The BHC is fully controlled via the control
panel on the front after the Direct immersion
heater has been switched on using switch S1.
The heater is be switched on via the ON/OFF
button (1). Set the room temperature to
between approx. + 6 °C and + 30 °C on the
room thermostat (3).
After the adjusted ambient temperature has
been reached, it will remain constantly, until the
appliance is switched off (the heating capacity
of the appliance must correspond at least to
the necessary heat requirement of the room).
Rapid heating function
With the rapid-heating-function the imersion
heater (if switch on) and the rapid-heater
(A2) will run for the preselected period for
continuous operation, regardless of the tem-
perature set on the room thermostat.
The heating time can be set at ¼ h, ½ h, 1 h
or 2 h on the short-time timer (6) and is acti-
vated by the rapid-heating button (7).
If the heating time is to be ended before the
end of the set period, the rapid heating button
must be pressed again.
Frost protection
In the event of a lengthy absence, the room
temperature should not fall below approx.
+6 °C (frost protection) and the room ther-
mostat should be turned to the à position
and the appliance must remain switched on
(observe the heating capacity of the appliance
and heat requirement of the room).
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Stiebel Eltron Thermofan Duo BHC 175 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Stiebel Eltron Thermofan Duo BHC 175 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 2,59 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info