The connection leads from the operating pa-
nel to the discharge control unit is to be laid
and secured in the same way as the existing
leads to the operating panel. They must not
come in contact with the intermediate wall or
the heating element connections.
2.2.2 Circuit diagram designations
X1 Mains connection terminal
X2 Connection terminal
Discharge control unit
A2 Electronic discharge control
B2 Room temperature sensor - discharge
R2 Adjuster - discharge
S2 ON/OFF switch, discharge control unit
X25 Internal connection strip A1-A2
2.2.3 Night time heating reduction
- connection of an external time-
clock
After installation, a switch or timeclock should
be wired to terminals L and TA on terminal
block X2. A temperature reduction of appro-
ximately 4 K can then be achieved.
The wiring for this modification must be pro-
vided by the installer, they are not included in
the kit.
2.3 Function test
Set the ON/OFF switch to the position " " .
Now rotate the temperature selector button
until the blower of the storage heater swit-
ches on. If the blower does not switch on, the
operating and fault displays on the charge and
discharge control units are to be observed.
2.3.1 Operating and fault display on
the electronic charging regulator
LED lights "green" No fault
The charge control unit is working perfectly.
LED lights "red" Fault
a) The selector button for charging (R1)
and/or the core sensor (B1) is defective
or not connected.
b) The plug bridge for reducing the degree
of charge at the discharge control unit is
missing.
No charging is taking place.
LED lights "orange" Fault at the dischatge
control unit
a) Discharge control unit is defective.
b) Potentiometer for setting the discharge is
defective and/or not connected.
The room temperature will be regulated to
about 22 °C.
c) Room temperature sensor defective and/
or not connected.
No discharge is taking place.
2.4 Handover
These Operating and Installation Instructions
belong to the unit and are to be kept in a safe
4. Garantie
3. Environment and re-
cycling
Please help us to protect the environment by
disposing of the packaging in accordance with
the national regulations for waste processing.
For guarantee please refer to the respective
terms and conditions of supply for your coun-
try.
The installation, electrical connection
and fi rst operation of this appliance
should be carried out by a qualifi ed installer.
The company does not accept liability
for failure of any goods supplied which
are not installed in accordance with the
manufacturer's instructions.
place by the owner. In the event of change of
ownership, they are to be handed over to the
new owner. In the event of any maintenance
or repair work being necessary, the qualified
installer is to be provided with the Operating
and Installation Instructions in order to consult
them.
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Stiebel Eltron RTI-EP2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Stiebel Eltron RTI-EP2 in the language / languages: English, German, Dutch, French, Spanish as an attachment in your email.

The manual is 4,39 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info