469639
9
Zoom out
Zoom in
Previous page
1/20
Next page
9
English
"CLICK"
X23
X21
X20
TA LE` LH LH` LE N
TA LE` LH LH` LE N
A1
Z1
Z1
A
2
Z2
Z2
TALELHLHLENNNNNLL-SH
TALELHLHLENNNNNLL-SH
LNLE
3
2
1
L3 L2 L1
A1
Z1
AC
D
C
A2
Z2
8
0x
P
S
80
x
N
S
6
8/72
x
A
C
3
7
/40x
A
C
I
II
III
IV
X15
X13
X12
X11
X10
X14
N
LE
3
2
1
L3 L2 L1
X25
X25
I
80 % PS
80
%
PS
II
80 % NS
80
%
NS
III
68/72 %
68/72 %
IV
37/40 %
37/40
%
X15 X14
X13
R2
A1
A2
A1
Z1
Z1
A2
Z2
Z2
TALELHLHLENNNNNLL-SH
TALELHLHLENNNNNLL-SH
LNLE
3
2
1 L3L2L1
A1
Z1
AC
DC
A2
Z2
80x PS
80x NS
68/72x AC
37/40x AC
I
II
III
IV
X
1
5
X
1
3
X
1
2
X
1
1
X
1
0
X
1
4
I
II
III
IV
2x
B2
B2
R2
8713.01
8715.01
8714.01
8716.01
X2
Push the temperature selector button
(R2) into the operating panel and turn it
as far as the left-hand stop.
Rotate the shaft of the potentiometer as
far as the left-hand stop.
Engage the potentiometer into the opera-
ting panel from the switchbox side (check
that the potentiometer shaft is properly
located).
Lay the 3-pole connection lead of the po-
tentiometer along behind the angle plate
to the plug-in location of the discharge
control unit (in this situation, fix the con-
nection lead to the operating panel and
the angle plate by means of the cable
holder).
Pivot the angle plate located in the switch-
box forwards in order to accommodate
the mains connection terminals, after relea-
sing (not unscrewing) the screw located in
the rear wall.
Plug the connection lead (X25) on the di-
scharge control unit (A2) onto the charge
control unit (A1).
Guide the 6-pin plug connector of the di-
scharge control unit along behind the angle
plate and upwards, insert it form above
into the plug-in locations „TA“ to „N“ of
the connection terminal X2, and screw it
tight (push the cable harness into the cable
holder provided).
Plug the discharge control unit into the
longitudinal holes located above the charge
control unit and engage it in position.
Screw the room temperature sensor (B2)
with two screws (2.9 x 6.5) to the front
inclined edge of the baseplate. Plug the
connection cable into the plug-in location
X20 of the discharge control unit.
Plug the connection lead of the potentio-
meter into the plug-in location X21 of the
discharge control unit.
Guide the separate leads provided along
behind the angle plate and connect them
as shown in the following table (to the ter-
minals X1 and X2 from below):
from to
Lead (brown) LE`(X2) S2 (bottom
plug-in location)
Lead (black)
L (X1) S2 (top plug-
in location)
Designation Laying
The leads must not come in contact
with the operating panel conductor
plate or simply insulated leads for safety ex-
tra-low voltage (SELV).
Incorporate the leads to the S2 switch into
the existing cable harness (drillers can be
opened and then closed again).
Pivot the angle plate back to the rear again
and screw it tight.
Secure the side wall, front wall, and air out-
let and inlet grilles to the appliance once
again (respect the installation sequence).
The toothed disks must be inserted
beneath the securing screws of the
side wall and the front wall (protective con-
ductor connection).
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Stiebel Eltron RTI-E3 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Stiebel Eltron RTI-E3 in the language / languages: English, German, Dutch, French, Spanish as an attachment in your email.

The manual is 4,39 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info