650337
28
Zoom out
Zoom in
Previous page
1/124
Next page
28 |DHE SLi www.stiebel-eltron.com
INSTALLATION
Safety
INSTALLATION
7. Safety
Only a qualified contractor should carry out installation, commis-
sioning, maintenance and repair of the appliance.
7.1 General safety instructions
We guarantee trouble-free function and operational reliability
only if the original accessories and spare parts intended for the
appliance are used.
!
Material damage
Observe the maximum inlet temperature. The appliance
can be damaged by higher temperatures. You can limit
the maximum inlet temperature by installing a central
thermostatic valve (see chapter "Appliance description/
Accessories").
7.2 Instructions, standards and regulations
Note
Observe all applicable national and local instructions and
regulations, e.g. DIN1988 / DINEN806 in Germany.
- The protection rating IP 25 (hoseproof) can only be ensured
with a correctly fitted cable grommet.
- The specific electrical resistance of the water must not fall
below that stated on the type plate. In a linked water net-
work, observe the lowest electrical water resistance (see
chapter "Specification / Application areas"). Your water
supply utility will advise you of the specific electrical water
resistance or conductivity.
8. Appliance description
8.1 Standard delivery
Delivered with the appliance:
- Mounting bracket
- Installation template
- 2 twin connectors
- Cross-piece
- Tee
- Flat gaskets
- Strainer
- Plastic profile washer
- Plastic connection pieces/ installation aid
- Cover and back panel guides
8.2 Accessories
Remote controls
- FFB 1 SL - Wireless remote control
Control from two locations
- FFB 2 SL - Wireless remote control
Wireless remote control unit as extension of the FFB 1 SL
- FB 1 SL - Hardwired remote control
Control only with remote control unit, suitable for self-sup-
porting installation
Taps/valves
- MEKD - kitchen pressure tap
- MEBD - bath pressure tap
Plug G½A
The plugs are required if you use pressure taps for finished walls
other than the ones recommended in the accessories.
Installation set for finished walls
- Solder fitting - copper pipe for solder connection Ø12mm
- Compression fitting - copper pipe
- Compression fitting - plastic pipe (suitable for Viega: San-
fix-Plus or Sanfix-Fosta)
Universal mounting frame
Mounting frame with electrical connections.
Pipe assembly for undersink appliances
This assembly for undersink installation is required if you need to
have the water connections (G⅜A) above the appliance.
Pipe assembly for offset installation
This pipe assembly with pipe bends is required if you need to
have the appliance vertically offset against the water connection
by approx. 90mm downwards.
Pipe assembly for replacing a gas water heater
This pipe assembly is required if the installation has existing gas
water heater connections (cold water connection on the left and
DHW connection on the right).
Pipe assembly DHB water plug-in couplings
2 water plug-in couplings allow the appliance to be connected to
the available water plug-in connections of a DHB.
Load shedding relay (LR 1-A)
The load shedding relay which needs to be installed in the dis-
tribution board provides priority control for the instantaneous
water heater when operating, for example, electric storage heat-
ers simultaneously.
ZTA 3/4 - central thermostatic valve
Thermostatic valve for central premixing, for example for an in-
stantaneous water heater with a solar thermal system.
28


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Stiebel Eltron DHE 24 SLi at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Stiebel Eltron DHE 24 SLi in the language / languages: English, German, Dutch, French, Polish as an attachment in your email.

The manual is 43,91 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info