650334
37
Zoom out
Zoom in
Previous page
1/124
Next page
ENGLISH
www.stiebel-eltron.com DHE SLi | 37
INSTALLATION
Troubleshooting
Possible indications of diagnostic traffic light (LED)
Red Illuminates in case of faults
Yellow Illuminates in heating mode
Green Flashing: appliance is supplied with mains power
Fault Cause Diagnostic traf-
fic light
Remedy
The appliance does not
heat up/ the set tem-
perature is not reached.
There is no mains voltage. No LED illuminates Check the MCB/fuse in your fuse box.
The safety switch (AE 3) has
responded.
No LED illuminates
Remove the cause of the fault.
Protect the system against overheating by opening a draw-off valve downstream
of the appliance for one minute. This cools down the heating system. Activate the
safety switch by pressing the pushbutton on the safety switch (see also chapter
"Commissioning").
The PCB is faulty. No LED illuminates Check the PCB and replace if necessary.
A phase has failed. Flashing green LED,
yellow LED on
Check the MCB/fuse in your fuse box.
The inlet temperature is
>55°C.
Flashing green LED,
red LED illuminates
Limit the inlet temperature.
The flow rate sensor (DFE) is
faulty or not attached.
Flashing green LED,
yellow LED off
Check the connection of the flow rate sensor and replace if necessary.
The heater is faulty. Flashing green LED,
yellow LED on
Check the heater and replace if necessary.
The inlet sensor is faulty. Flashing green LED,
red LED illuminates
Replace the PCB.
The outlet sensor is faulty. Flashing green LED,
red LED illuminates
Check the connection of the outlet sensor and replace if necessary.
A fault in the safety PCB.
Flashing green LED,
red LED only during
draw-off
Connect the connecting cable from the safety switch and check the safety switch.
A loose or faulty connecting
cable to the set value trans-
ducer.
Green LED flashes
Connect the connecting cable from the set value transducer and check the con-
necting cable.
The set value transducer is
faulty.
Green LED flashes Check the set value transducer and replace it if required.
The display on the ap-
pliance is completely off.
A loose connecting cable to the
set value transducer.
Green LED flashes Connect the connecting cable at the set value transducer and check the connect-
ing cable.
The programming PCB is faulty. Green LED flashes Check the programming unit and replace if necessary.
The flow rate is too low.
The shower head/ aerators are
scaled up.
Descale or if necessary replace the shower head/ aerators.
The strainer is contaminated. Clean the strainer.
The set value cannot be
adjusted higher than
43°C, nor can a differ-
ent set temperature be
selected.
Dynamic anti-scalding protec-
tion is activated.
Green LED flashes
The dynamic anti-scalding protection is deactivated again 2 minutes after draw-
off.
Childproofing and/or tempera-
ture limiting is activated.
Green LED flashes Disable temperature limiting.
Cold water flows briefly
during draw-off.
The flow rate
(<2 l/min) is too low.
The appliance restarts automatically when a flow rate of >2.5 l/min has been
detected.
The air sensor detects the
presence of air in the water and
briefly switches the heater off.
The appliance restarts after one minute.
37


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Stiebel Eltron DHE 18 SLi 25 A at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Stiebel Eltron DHE 18 SLi 25 A in the language / languages: English, German, Dutch, French, Polish as an attachment in your email.

The manual is 43,91 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info