34 |DHE SLi www.stiebel-eltron.com
INSTALLATION
Installation
Mounting bracket for appliance replacement
Am existing StiebelEltron mounting bracket may be used when
replacing appliances (except instantaneous water heater DHF).
Break through the back panel of the appliance for the thread-
ed stud on the pre-installed mounting bracket.
DHF replacement
26�02�02�0815�
Reposition the threaded stud on the mounting bracket (the
stud has a self-tapping thread).
Rotate the mounting bracket through 180° and mount it on
the wall (the DHF logo is then turned towards the reader).
Installation with offset tiles
110
20
26�02�02�1066�
2
1
1 Minimum contact area of the appliance
2 Maximum tile offset
Adjust the wall clearance and lock the back panel with the
fixing toggle by turning it clockwise through 90°.
Turned appliance cover
The appliance cover can be turned for undersink installation.
electr onic
comfor t
electr
onic comf or
t
26�02�02�0553
Remove the programming unit from the appliance cover by
pressing the locking hooks and taking out the programming
unit.
Turn the appliance cover (not the appliance) and refit the
programming unit, ensuring that all locking hooks click into
place. When clicking the locking hooks into place, make sure
you press against the inner side of the appliance cover (shad-
ed area).
Plug the set value transducer cable into the PCB (see chapter
"Commissioning").
Hook the appliance cover back in at the bottom and pivot it
up onto the back panel.
Ensure the all-round seal of the back panel sits tightly by
pushing the cover gently forwards and back.
Secure the appliance cover.
Operation with preheated water
By installing a central thermostatic valve you will limit the max-
imum inlet temperature (see chapter "Appliance description/
Accessories").
34


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Stiebel Eltron DHE 18 SLi 25 A at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Stiebel Eltron DHE 18 SLi 25 A in the language / languages: English, German, Dutch, French, Polish as an attachment in your email.

The manual is 43,91 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info