650321
17
Zoom out
Zoom in
Previous page
1/20
Next page
ENGLISH
www.stiebel-eltron.com DHB-E AU| 17
INSTALLATION
Specication
15.6 Fault conditions
In case of faults, loads up to 95°C at a pressure of 1.0MPa can
occur temporarily in the installation.
15.7 Data table
DHB-E 13 AU DHB-E 18 AU DHB-E 27 AU
232360 233986 233987
Electrical data
Rated voltage V 380 400 415 380 400 415 380 400 415
Rated output kW 12.2 13.5 14.5 16.2 18 19.4 23.5 26 28
Rated current A 18.5 19.5 20.2 24.7 26 27 35.6 37.7 38.9
Fuse/MCB rating A 20 20 20 25 25 32 40 40 40
Phases 3/PE 3/PE 3/PE
Frequency Hz 50/60 50/60 50/- 50/60 50/60 50/- 50/- 50/- 50/-
Specific resistance ρ
15
≥ (at ϑcold ≤25°C) Ω cm 900 900 1000 900 900 1000 900 900 1000
Specific conductivity σ
15
≤ (at ϑcold ≤25°C) μS/cm 1111 1111 1000 1111 1111 1000 1111 1111 1000
Specific resistance ρ
15
≥ (at ϑcold ≤45°C) Ω cm 1200 1200 13000 1200 1200 1300 1200 1200 1300
Specific conductivity σ
15
≤ (at ϑcold ≤45°C) μS/cm 833 833 770 833 833 770 833 833 770
Max. mains impedance at 50Hz Ω 0.474 0.450 0.433 0.316 0.300 0.289
Max. mains impedance at 60Hz Ω 0.392 0.372
Connections
Water connection G 1/2 A G 1/2 A G 1/2 A
Application limits
Max. permissible pressure MPa 1 1 1
Max. inlet temperature for reheating °C 45 45 45
Values
Max. permissible inlet temperature °C 60 60 60
On l/min >3.0 >3.0 >3.0
Flow rate for pressure drop l/min 5.2 5.2 7.7
Pressure drop at flow rate MPa 0.08 (0.06 without DMB) 0.08 (0.06 without DMB) 0.16 (0.12 without DMB)
Flow rate limit at l/min 7.5 7.5 8.5
DHW delivery l/min 6.9 9.2 13.8
Δϑ on delivery K 28 28 28
Hydraulic data
Nominal capacity l 0.4 0.4 0.4
Versions
Connected load options -
Temperature setting °C 30-50 30-60 30-60
Safety category 1 1 1
Insulating block Plastic Plastic Plastic
Heating system Bare wire Bare wire Bare wire
Cover and back panel Plastic Plastic Plastic
Colour white white white
IP rating IP25 IP25 IP25
Dimensions
Height mm 478 478 478
Width mm 225 225 225
Depth mm 105 105 105
Weights
Weight kg 3.6 3.6 3.6
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Stiebel Eltron DHB-E 27 AU at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Stiebel Eltron DHB-E 27 AU in the language / languages: English as an attachment in your email.

The manual is 9,64 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info