650330
23
Zoom out
Zoom in
Previous page
1/116
Next page
OPERATION
Appliance description
ENGLISH
www.stiebel-eltron.com DHB-E SLi | 23
2.3 Test symbols
See type plate on the appliance.
3. Appliance description
The electronically controlled instantaneous water heater main-
tains a constant outlet temperature up to its output limit, irre-
spective of the inlet temperature.
The appliance heats the water directly at the draw-off point, as
soon as you turn on the hot water tap. The short pipe runs ensure
that energy and water losses are minimal.
For the start flow rate, see chapter "Installation/ Specification/
Data table, On".
The DHW output depends on the cold water temperature, the
heating output, the flow rate and the selected set temperature.
Water will not be reheated if the maximum inlet temperature for
reheating is exceeded.
DHW temperature
The DHW outlet temperature can be variably adjusted.
Temperature limit / Anti-scalding protection
The maximum outlet temperature for the appliance can be limited
to 43°C. For this, contact your local heating contractor.
Heating system
The bare wire heating system has a pressure-tested plastic casing.
The heating system is suitable for (both) soft and hard water and
is largely resistant to scale build-up. This heating system ensures
rapid and efficient DHW availability.
Note
The appliance is equipped with an air detector that large-
ly prevents damage to the heating system. If, during op-
eration, air is drawn into the appliance, the appliance
shuts down for one minute, thereby protecting the heat-
ing system.
4. Operation
30
60
45
35
40
50
55
26�02�02�1381
Turn the temperature selector to the required position.
If the outlet temperature fails to reach the required level with the
tap fully open and the temperature selector set to maximum, then
more water is flowing through the appliance than can be heated
by the heating element.
Reduce the flow rate at the tap.
4.1 Recommended settings
Thermostatic valve
If the appliance is being operated with a thermostatic valve, we
recommend setting the temperature on the appliance to maxi-
mum. The required temperature can then be set at the thermo-
static valve.
Following an interruption to the water supply
!
Material losses
To ensure that the bare wire heating system is not dam-
aged following an interruption to the water supply, the
appliance must be restarted taking the following steps.
Disconnect the appliance from the power supply by
removing the fuses/tripping the MCBs.
Open the tap for one minute until the appliance and
its upstream cold water inlet line are free of air.
Switch the mains power back ON again.
4.2 Temperature limit / Anti-scalding protection
The maximum outlet temperature for the appliance can be limited
to 43°C. For this, contact your local heating contractor.
23


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Stiebel Eltron DHB-E 21 SLi electronic at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Stiebel Eltron DHB-E 21 SLi electronic in the language / languages: English, German, Dutch, French, Polish as an attachment in your email.

The manual is 31,29 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Stiebel Eltron DHB-E 21 SLi electronic

Stiebel Eltron DHB-E 21 SLi electronic Usermanual and installation guide - English - 20 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info