14. Specification
14.1 Dimensioned drawing
478
100
414
44
105≤ 20225
140
30
35
35
114
368
338
47
b02
b01
c01c06
D0000017973
b01 Entry electrical cables
b02 Entry electrical cables 1
c01 Cold water inlet male thread G 1/2 A
c06 DHW outlet male thread G 1/2 A
14.2 Wiring diagram
3/PE~380 - 415V
8502�02�0005�
1 Heater
2 High limit safety cut-out
3 Safety pressure limiter
14.3 Mixed water volume / outlet volume
Available temperature approx. 38 °C in the shower, for hand
washing, filling the bath etc.

Appliance kW 11 18 21 24 27
Cold water inlet
6 °C l/min 5.0 8.0 9.4 10.7 12.1
temperature
10 °C l/min 5.7 9.2 10.7 12.3 13.8
14 °C l/min 6.6 10.7 12.5 14.5 16.1
Outlet temperature approx. 60 °C for the kitchen sink and when
using thermostatic valves.

Appliance kW 11 18 21 24 27
Cold water inlet
6 °C l/min 2.9 4.8 5.6 6.4 7.2
temperature
10 °C l/min 3.2 5.2 6.0 6.9 7.7
14 °C l/min 3.4 5.6 6.5 7.5 8.4
The values in the table are relative to a rated voltage of 400 V. The
outlet volume is subject to the available supply pressure and the
available mains voltage.
14.4 Application areas
Specific electrical resistance and specific electrical conductivity

Standard value
at 15 °C
at 20 °C
at 25 °C
Resistance Ω cm ≥ 900 ≥ 1000 ≥ 800 ≥ 890 ≥ 735 ≥ 815
Conductivity mS/m ≤ 111 ≤ 100 ≤ 125 ≤ 112 ≤ 136 ≤ 123
Conductivity µs/cm ≤ 1110 ≤ 1000 ≤ 1250 ≤ 1120 ≤ 1360 ≤ 1230

Standard value
at 15 °C
at 20 °C
at 25°C
Resistance Ω cm ≥ 1200 ≥ 1300 ≥ 1070 ≥ 1175 ≥ 985 ≥ 1072
Conductivity mS/m ≤ 83 ≤ 77 ≤ 94 ≤ 85 ≤ 101 ≤ 93
Conductivity µs/cm ≤ 830 ≤ 770 ≤ 940 ≤ 850 ≤ 1010 ≤ 930
14.5 Pressure drop
14.5.1 Taps/valves

Mono-lever mixer tap, approx. MPa 0.04 - 0.08
Thermostatic valve, approx. MPa 0.03 - 0.05
Hand shower, approx. MPa 0.03 - 0.15
14.5.2 Sizing the pipework
When calculating the size of the pipework, a pressure drop for the
appliance of 0.1 MPa is recommended.
14.6 Fault conditions
In case of faults, loads up to a maximum of 95 °C at a pressure of
1.2 MPa can occur temporarily in the installation.
14.7 Country-specific approvals and certifications
Test symbols can be seen on the type plate.
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Stiebel Eltron DHB-E 21 SLi electronic at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Stiebel Eltron DHB-E 21 SLi electronic in the language / languages: English as an attachment in your email.

The manual is 7 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Stiebel Eltron DHB-E 21 SLi electronic

Stiebel Eltron DHB-E 21 SLi electronic Usermanual and installation guide - English, German, Dutch, French, Polish - 116 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info