8. Appliance description
The bare wire heating system is suitable for hard and soft water
areas. The heater has low susceptibility to scale build-up.
The appliance is suitable for heating cold water or for reheating
preheated water. For temperatures, see chapter "Specification /
Data table".
The max. inlet temperature for reheating must not be exceeded.
There will be no reheating, if the inlet temperatures exceed this
maximum value.
Observe the "Max. inlet temperature". The appliance can be
damaged at higher temperatures. If a "central thermostat" is
installed (see chapter "Installation / Accessories"), you can limit
the "Max. inlet temperature".
The outlet temperature can be infinitely adjusted. The electronic
control unit enables automatic matching of the electrical output
corresponding to the selected temperature subject to the actual
throughput.
8.1 Standard delivery
- Mounting bracket
- Installation template
- Twin nipple
- Cross-piece
- Tee
- Flat packing
- Sieve
- Flow limiter
- Plastic profile washer
- Plastic cap
- Flexible plastic couplings
- Cap and back panel guides
8.2 Installation
The following conditions have been prepared for the appliance
at the factory:
- Power supply from "below", installation on unfinished walls
- Water connection, installation on unfinished walls
The appliance must be fitted vertically, over or undersink, to a
solid wall.
8.3 Temperature limiting/anti-scalding protection
The maximum temperature can be limited to 43°C via the user
interface on the appliance cap. The following steps are necessary
for this procedure:
Remove the appliance cap.
Remove the electronic PCB from the user interface on the
appliance cap. Be careful of the snap-on hooks.
Move the plug from left to right (position "43 °C").
Refit the user interface, ensuring the snap-on hooks click into
place. Observe the positions of the pushbutton and shaft.
CAUTION Burns
If operating with preheated water, the set temperature
limit and anti-scalding protection may be ineffective.
In this case, restrict the temperature at the
upstream central thermostatic valve; see chapter
Accessories”.
2602�02�0833
8.4 Installation versions
The following installation versions are possible/permissible:
- Power supply for unfinished walls - from above
- Power supply for finished walls
- Water installation for finished walls
- Installation with repositioned appliance cap
- Installation for offset tiles
- Installation of a load shedding relay
8.5 Accessories
Taps
- WKMD – twin-lever pressure-tested kitchen tap
- WBMD – twin-lever pressure-tested bath tap
Plug G½A
These plugs are required if you use twin-lever pressure-tested
taps for finished walls other than the ones recommended by us.
Installation sets for installation on finished walls
- Solder fitting – copper pipe for solder connection Ø12 mm.
- Compression fitting – copper pipe.
- Compression fitting – plastic pipe
(suitable for Viega: Sanfix-Plus or Sanfix-Fosta).
Universal mounting frame
- Mounting frame with electrical wiring.
Pipe set for undersink appliances
The set for undersink installation is required if you want to have
the water connections (G⅜A) above the appliance.
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Stiebel Eltron DHB-E 18 SLi electronic at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Stiebel Eltron DHB-E 18 SLi electronic in the language / languages: English as an attachment in your email.

The manual is 7 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Stiebel Eltron DHB-E 18 SLi electronic

Stiebel Eltron DHB-E 18 SLi electronic Usermanual and installation guide - English, German, Dutch, French, Polish - 116 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info