13. Troubleshooting
WARNING Risk of electrocution
To test the appliance, it must be supplied with power.
13.1 Display options LED diagnostic "traffic lights"

red illuminates in case of faults
yellow illuminates when the appliance is heating water
green flashing: The appliance is supplied with power
13.2 Fault table


 
The appliance does not start. The shower head / perlators are scaled up. Descale or if necessary replace the shower head /
perlators.
Inadequate flow rate. The sieve in the appliance is dirty. Clean the sieve.
Set temperature is not achieved. One phase down. Check the MCB/fuse in your fuse box.
Heating does not switch on. The air sensor detects the presence of air in the water
and briefly switches the heater off.
The appliance restarts after one minute.
No hot water and no "traffic light" display. The MCB/fuse has responded/blown. Check the MCB/fuse in your fuse box.
Safety pressure limiter AP 3 has tripped. Remove the cause of the fault (e.g. faulty pressure
washer).
Protect the system against overheating by opening
a draw-off valve downstream of the appliance for
1 minute. This depressurises and cools down the
heating system.
Activate the safety pressure switch at flow pressure
by pressing the reset button.
The PCB is faulty. Check the PCB and replace if necessary.
Traffic light display: Green flashing
No hot water at flow rate of
>3l/min.
Flow sensor (DFE) is not plugged in.
Plug the flow sensor plug back in.
Flow sensor DFE is faulty. Check the flow sensor and replace if necessary.
The set temperature is not achieved.
The set value transducer or connecting cable is faulty or
the connecting cable is not attached.
Attach the connecting cable; replace the set value
transducer if required.
Temperature limiting is activated. Disable temperature limiting.
Traffic light display: Yellow constantly ON;
green flashing
No hot water at flow rate of >3l/min.
The high limit safety cut-out has responded or its lead
is broken.
Check the high limit safety cut-out and replace if
necessary.
The heating system is faulty. Measure the resistance of the heating system and
replace if necessary.
The PCB is faulty. Check the PCB and replace if necessary.
Traffic light display: yellow constantly ON;
green flashing
The outlet sensor is faulty. Check the connection and replace the outlet sensor
if necessary.
Set temperature is not achieved. Appliance operates at its output limit. Reduce the flow rate or install the flow limiter.
Traffic light display: red constantly ON; green
flashing
The outlet sensor is faulty. Check the connection and replace the outlet sensor
if necessary.
No hot water The cold water sensor is faulty. Check the PCB and replace if necessary.
Required temperature > 45 °C is not achieved. The cold water inlet temperature exceeds 45 °C. Reduce the cold water inlet temperature to the
appliance.
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Stiebel Eltron DHB-E 18 SLi 25A electronic at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Stiebel Eltron DHB-E 18 SLi 25A electronic in the language / languages: English as an attachment in your email.

The manual is 7 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Stiebel Eltron DHB-E 18 SLi 25A electronic

Stiebel Eltron DHB-E 18 SLi 25A electronic Usermanual and installation guide - English, German, Dutch, French, Polish - 116 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info