650328
11
Zoom out
Zoom in
Previous page
1/20
Next page
ENGLISH
 


Push the appliance over the stud of the mounting bracket, so
that it breaks through the soft seal.
Push the fixing toggle onto the stud of the mounting bracket
that penetrates the back panel.
Press the back panel firmly into place and lock the fixing
toggle by turning it through 90°.
Push the cable grommet over the power cable. For this, use
the installation aid. For a power cable of 10 or 16 mm², the
hole in the cable grommet must be enlarged. Click the cable
grommet into place in the back panel.
10.3.4 Connecting a load shedding relay
Install the load shedding relay in conjunction with other electric
appliances, e.g. electric storage heaters. The relay responds when
the instantaneous water heater starts. The load shedding relay is
available from Stiebel Eltron as a special accessory.
Note
Connect the phase that switches the load shedding relay
to the indicated terminal of the mains terminal in the
appliance.
2
1
8502�02�0003
1 Control cable to the contactor of the second appliance (e.g.
electric storage heater).
2 Control contact, opens when switching the instantaneous
water heater on.
10.3.5 Water installation for finished walls
Suitable pressure taps WKMD or WBMD for installation on finished
walls are available as special accessories.
Fit the water plugs with gaskets to seal the connection
(below the plaster). With Stiebel Eltron pressure taps, plugs
and gaskets are part of the standard delivery. For third party
pressure taps, plugs and gaskets can be ordered as special
accessories.
Install the tap.
Push the lower part of the back panel under the connection
pipes of the pressure tap and click it into place in the back
panel.
Secure the connection pipes to the appliance.
2602�02�0528
WKMD
WBMD
10.3.6 Water installation for finished walls with solder/
compression fitting
With the special accessories "solder fitting" or "compression fitting"
(see "Accessories"), copper or plastic pipes can be connected in
installations for finished walls.
With special accessory "solder tting", a threaded connection with
on-site 12 mm copper pipes is possible. For this the following
steps are required:
Push the union nuts over the connection pipes.
Solder the inserts to the copper pipes.
Push the lower part of the back panel under the connection
pipes and click it into place in the back panel.
Secure the connection pipes to the appliance.
Note
Observe the valve manufacturer's installation instructions.
10.3.7 Water installation for finished walls, fitting the
appliance cap
The following steps are necessary to complete the appliance cap
installation.
Cleanly break out the knock-out in the appliance cap. If
necessary, use a file.
Break the tabs out of the cap guides.
Note
The appliance can be sealed by fitting the cap guides with
tabs if the tap pipes are slightly offset. The back panel
guides are not required in this case.
Click the cap guides provided into place in the knock-outs.
Position the back panel guides on the pipes and push them
together. Then push the guides until they meet the back
panel.
Secure the back panel at the bottom with a screw. This is
also relevant if flexible water supply systems are used.
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Stiebel Eltron DHB-E 18 SLi 25A electronic at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Stiebel Eltron DHB-E 18 SLi 25A electronic in the language / languages: English as an attachment in your email.

The manual is 7 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Stiebel Eltron DHB-E 18 SLi 25A electronic

Stiebel Eltron DHB-E 18 SLi 25A electronic Usermanual and installation guide - English, German, Dutch, French, Polish - 116 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info