650320
14
Zoom out
Zoom in
Previous page
1/20
Next page
14 | DHB-E AU www.stiebel-eltron.com
INSTALLATION
Troubleshooting
13. Troubleshooting
WARNING Electrocution
In order to check the appliance it must be connected to
the power supply.
13.1 Indicator options for LED diagnostic traffic light
Indicator options
Red Illuminates in the event of a fault
Yellow Illuminates during heating mode
Green Flashing: Appliance is supplied with mains power
13.2 Fault table
Fault / diagnostic traffic light LED
display
Cause Remedy
The appliance does not start. The shower head / aerators are scaled up. Descale or if necessary replace the shower head / aera-
tors.
Inadequate flow rate. The strainer in the appliance is dirty. Clean the strainer.
The set temperature is not achieved. One phase down. Check the fuses/MCBs in your fuse box/distribution panel.
The heater switches off. The air sensor detects the presence of air in the water
and briefly interrupts the heating output.
The appliance restarts after one minute.
No hot water and no traffic light display.
The MCB/fuse has responded/blown. Check the fuses/MCBs in your fuse box/distribution panel.
Safety pressure limiter AP 3 has tripped.
Remove the cause of the fault (e.g. faulty pressure wash-
er).
Protect the heating system against overheating by open-
ing a draw-off valve downstream from the appliance for
one minute. This depressurises and cools down the heat-
ing system.
Activate the safety pressure limiter at flow pressure by
pressing the reset button; see also chapter "Commission-
ing/ Initial start-up".
The PCB is faulty. Check the PCB and replace if necessary.
Traffic light display: Green flashing
No hot water at flow rate >3l/min.
Flow sensor DFE is not plugged in. Plug the flow sensor plug back in.
Flow sensor DFE is faulty. Check the flow sensor and replace if necessary.
The set temperature is not achieved.
The set value transducer or connecting cable is faulty, or
the connecting cable is not attached.
Attach the connecting cable; replace the set value trans-
ducer if required.
Temperature limiting is activated. Disable temperature limiting.
Traffic light display: Yellow constantly on;
green flashing
No hot water at flow rate >3l/min.
The high limit safety cut-out has responded or its lead
is broken.
Check the high limit safety cut-out and replace if neces-
sary.
The heating system is faulty. Measure the resistance of the heater and replace if nec-
essary.
The PCB is faulty. Check the PCB and replace if necessary.
Traffic light display: yellow constantly on;
green flashing
The outlet sensor is faulty. Check the connection and replace the outlet sensor if
necessary.
Set temperature is not achieved. Appliance is operating at its output limit. Reduce the flow rate or install the flow limiter.
Traffic light display: red constantly on; green
flashing
The outlet sensor is faulty. Check the connection and replace the outlet sensor if
necessary.
No hot water
The cold water sensor is faulty. Check the PCB and replace if necessary.
Required temperature >45°C not achieved The cold water inlet temperature exceeds 45°C. Reduce the cold water inlet temperature to the appliance.
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Stiebel Eltron DHB-E 18 AU at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Stiebel Eltron DHB-E 18 AU in the language / languages: English as an attachment in your email.

The manual is 9,64 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info