650333
9
Zoom out
Zoom in
Previous page
1/20
Next page
ENGLISH
 


10.2.7 Fitting the sieve
Fit the sieve provided in the cold water inlet of the appliance.
Note
The sieve must always be fitted for the function of the
appliance to be guaranteed. If an appliance is being
replaced during installation, ensure that a sieve is
available.
2602�02�0856
10.2.8 Installing the DMB flow limiter
Position the flow limiter provided in the cold water inlet of
the appliance.
A second flow limiter is provided with the DHB-E 18/21/24 SLi.
Install the ow limiter with an output corresponding to that of
the appliance.
Flow limiter, see "flow rate limit" in chapter "Specification":
4.0 l/min = pink
7.5 l/min = blue
8.5 l/min = green
2602�02�0857
10.2.9 Mounting the appliance
The cable grommet pointing towards the wall may hinder the
mounting of the appliance close to the wall. To prevent such
problems, it is advisable to briefly press the cable grommet from
behind into the back panel, to reduce the stiffness or the grommet.
Remove the fixing toggle from the upper part of the back
panel (diagram "Mounting the appliance").
Route the power cable from behind through the cable
grommet until it rests against the cable sheath. Align the
power cable. If the cross-section of the power cable is
greater than 6mm, enlarge the hole in the cable grommet
(see also "Power supply for larger cross-sections").
Push the appliance over the stud of the mounting bracket, so
that it breaks through the soft seal. If necessary pierce the
soft seal with a screwdriver.
Put the fixing toggle onto the stud of the mounting bracket
that penetrates the back panel.
Press the back panel firmly into place and lock the fixing
toggle by turning it through 90°.
2602�02�0811
10.2.10 Finalising the water connection
2602�02�0858
10.2.11 Connecting the power supply
Connect the power cable to the mains terminal (see chapter
"Wiring diagram").
WARNING Risk of electrocution
Ensure that the appliance is connected to earth.
2602�02�1122
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Stiebel Eltron DHB-E 13 A at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Stiebel Eltron DHB-E 13 A in the language / languages: English as an attachment in your email.

The manual is 7 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info