Technical specifications
Installation instructions
Principle
GB
Dear Customer,
Congratulations on purchasing your new
STEINEL infrared sensor and thank you for the
confidence you have shown in us. You have
chosen a high-quality product that has been
manufactured, tested and packed with the
greatest care.
Please familiarise yourself with these instruc-
tions before attempting to install the unit. Be-
cause prolonged, reliable and trouble-free
operation will only be ensured if it is fitted and
used properly.
We hope your new infrared sensor will give you
lasting satisfaction.
The unit is equipped with pyro sensors that de-
tect the invisible heat emitted from moving ob-
jects (people, animals etc.). The heat detected
in this way is electronically converted into a
signal that switches ON a connected load
(e.g. a light). No heat radiation is detected
through obstacles, such as walls or panes of
glass, and will therefore not trigger the sensor.
Safety warnings
n This product must only be installed by a
qualified electrician in accordance with
national wiring regulations as defined in
VDE 08 29 (DIN EN 500090).
n Installed improperly, low-voltage products
can cause extremely serious personal injury
or damage to property.
n This product must never be connected to a
230 V AC power supply as it is intended for
connection to an extra-low voltage power
supply.
Operation
Note: To calibrate the product, please go to
www.knx.steinel.de
1. Issue physical address and generate
calibration programme in the ETS.
2. Load the physical address and calibration
programme into the presence detector.
When you are prompted, press the
programming button .
3. The red LED goes out once programming
has been successfully completed.
System components
Surface-mounting adapter
Sealing plug
Film shroud
Lens enclosure
Condensation water drainage hole
Wall mount / sensor unit
Corner wall mount (optional)
Plug-in terminals
Locking screw
Reach setting
Connect KNX bus
Programming button
Power supply lead, surface-mounted
Power supply lead, concealed
I
Dimensions (H x W x D): 114 x 74 x 128 mm
Power supply: KNX bus voltage
Angle of coverage: 300° with 180° angle of aperture, as well as sneak-by guard
for coverage directly below the sensor. Capability of masking
out individual segments
Reach: Adjustable in 3 directions independently of
each other by control dial, (2-20 m tangentially,
temperature-stabilised)
Sensor system: 4 sensors, 6 levels for long-distance detection and
5 for sneak-by guard,
1360 switching zones
Recommended
installation height: 2.00 - 2.50 m
Time setting: 1 min. - 15 min.
Manual override: selectable (4 hrs.) / (by remote control only)
Permanently OFF: selectable (6 hrs.) / (by remote control only)
IP rating: IP 54
Protection class: II
Temperature range: - 20 °C to + 50 °C
Electrical installation/Automatic mode
In selecting the wiring leads, it is important to
meet the wiring regulations laid down in VDE
08 29 (DIN EN 500090) - (see Safety warnings
on page 12).
II
GB
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Steinel sensIQ S KNX at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Steinel sensIQ S KNX in the language / languages: All languages as an attachment in your email.

The manual is 2,7 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info