592499
5
Zoom out
Zoom in
Previous page
1/10
Next page
The SensorLight can be put into operation as soon as
the enclosure has been fitted and the SensorLight
has been connected to the mains power supply.
Putting the light into operation manually at the light
switch turns it OFF after 10 secs. for the calibration
phase. Once calibrated, it is activated for the sensor
mode. It is not necessary to operate the light switch a
second time.
Reach setting (sensitivity)
Reach can be infinitely varied from
3 m to 8 m.
Adjustment control set to:
= minimum reach (3 m)
+ = maximum reach (8 m)
Factory setting: 8 m.
Reach is the term used to describe the diameter of
the more or less circular detection zone produced on
the ground after mounting the SensorLight at a height
of 2.5 m.
Time setting (switch-off delay)
Light ON duration can be infinitely
varied from 5 sec. to 15 min.
Adjustment control set to:
= shortest 'ON' time (5 sec.)
+ = longest 'ON' time (15 min.)
Factory setting: 5 sec.
Any movement detected before this time elapses will
re-start the timer. The shortest time setting is recom-
mended when adjusting the detection zone and per-
forming a functional test.
Note: After the light switches
'OFF', it takes approx.
1 sec. before it is able to start detecting movement
again. The light will only switch
'ON' in response to
movement once this period has elapsed.
Twilight setting (response threshold)
The response threshold can be
infinitely varied from 2 – 2000 lux.
Adjustment control set to:
= Night-time operation (2 lux)
= daylight operation (2000 lux)
Factory setting: 2000 lux
When adjusting the detection zone and performing
the walk test in daylight, the control must be set
to .
Functions
- 9 -
Functional Warranty
This STEINEL product has been manufactured with
great care, tested for proper operation and safety in
accordance with applicable regulations and then sub-
jected to random sample inspection. STEINEL guar-
antees that it is perfect condition and proper working
order. The warranty period is 36 months, starting on
the date of sale to the consumer. We will remedy
defects caused by material flaws or manufacturing
faults. The warranty will be met by repair or replace-
ment at our own discretion. The warranty shall not
cover damage to wear parts, damage or defects
caused by improper treatment or maintenance.
Further consequential damage to other objects is
excluded.
Claims under the warranty will only be accepted if the
unit is sent fully assembled and well packed complete
with a brief description of the fault, a receipt or
invoice (date of purchase and dealer's stamp) to the
appropriate Service Centre.
Repair Service:
Our Customer Service Department will
repair faults not covered by warranty
or after the warranty period. Please
send the product well packed to your
nearest Service Centre.
Declaration of conformity
This product complies with
- Low Voltage Directive 2006/95/EC
- EMC Directive 2004/108/EC
- RoHS Directive 2002/95/EC
- R&TTE Directive 1999/05/EC
Installation
Important: Make sure the installation site is
not sub-
ject to
vibration.
Connecting a dimmer will result in damage to the
SensorLight.
Please note that the light must be protected by a 10 A
circuit breaker.
1. Hold enclosure against the wall/ceiling and
mark drill holes, paying attention to any existing
wiring in the wall/ceiling.
2. Drill the holes, insert wall plugs (6 mm dia.).
3. Pierce sealing plug for power supply lead.
4. Pass power supply leads through.
5. Screw enclosure into place.
6. Connecting the mains power supply lead (see fig.).
The mains power supply lead is a 3-core cable:
L = phase conductor (usually black or brown)
N = neutral conductor (usually blue)
PE = protective earth conductor (green/yellow)
If you are in any doubt, identify the conductors using
a voltage tester; switch
'OFF' the current again.
Connect the phase conductor (L) and neutral con-
ductor (N) to the terminal block. Insulate any PE pro-
tective earth conductor with adhesive tape.
Technical specifications
Dimensions (HxWxD): 300 x 300 x 110 mm
Material: Aluminium (heat sink),
polycarbonate (base/diffuser)
Mains voltage: 230 – 240 V, 50 Hz
Output: 16 W LED / 460 lm
Colour temperature: 3200 kelvin (warm white)
LED life expectancy: 50.000 hours
HF-system: 5.8 GHz
Angle of coverage: 360° with 160° aperture angle also through glass, wood and stud walls
Detection reach: 3 m – 8 m all round
Twilight setting: 2 – 2000 lux
Time setting: 5 sec. to 15 min.
IP rating: IP 20
Protection class: II
Power consumption: approx. 0.9 W
Temperature range: -10° C to +50° C
- 8 -
7. Set functions , , .
8. Fit glass shade and turn clockwise to secure it in
place.
Surface wiring:
Surface wiring can be carried out as shown in
diagram I on page 2.
GB
Ø 3 m – 8 m dia.
5 sec. - 15 min.
+
+
2 – 2000 lux
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Steinel RS LED D1 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Steinel RS LED D1 in the language / languages: English, German, Polish, Spanish as an attachment in your email.

The manual is 0,71 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info