592453
7
Zoom out
Zoom in
Previous page
1/54
Next page
12
Getting Started
123
456
789
1
Detach heating head
from handle. To do this,
release bayonet catch
by pulling trigger and
turning heating head.
2
Insert the enclosed feed
rod into the handle.
3
Push the feed rod
further into the handle
to the stop point.
4
Insert sealed cartridge
into heating head .
5
Reassemble heating
head and handle (turn
bayonet catch so that it
clips into place.).
6
Plug in power cord in
order to supply base
station with mains
power. Green diode will
light up.
7
Insert gun into contact
slots on base station .
Glue will now be heated
up.
Status indicator:
RED: heating up
(approx. 10–13 minutes).
8
Status indicator:
GREEN: Glue has
reached bonding tem-
perature. Remove hot-
melt glue gun from
base station .
9
Unscrew cap (store
in handle ). Pull trig-
ger to commence glu-
ing. Feed rod will ad-
vance and press against
cartridge plonger. Glue
will emerge from
nozzle.
13
Important Information
Tips on achieving particularly good glueing results
Perfect operation will
only be ensured by using
genuine STEINEL glue
cartridges.
The materials to be
glued should be free of
grease, dry and absolu-
tely clean (clean with a
paper tissue, for exam-
ple). Important: do not
use any solvents or simi-
lar liquid cleaners.
Furthermore, it is recom-
mended to roughly sand
the surfaces to be glued,
particularly for treated
metals such as anodised
aluminium, galvanized
metal for example.
When glueing glass, the
bond should not be
exposed continuously to
direct sunlight (UV radia-
tion). (Tape over the
back of the bond, if
necessary.)
The surfaces being
glued together should
be at room temperature.
Before applying glue to
cold materials, e.g. tiles,
marble, etc., warm them
(with a hot air gun, for
instance) so that glue
does not harden too
quickly and shorten
working time.
Fix heavy items in
position immediately
after glueing (e.g. using
adhesive tape).
Optimum bond strength
is achieved by mating up
the two contact surfaces
immediately after apply-
ing glue.
Hardened, excess glue
can easily be removed
with a knife.
Bonds can be separated
again by applying heat
(130 °C, e.g. using a hot
air gun).
Apply the glue in dabs or
beads. Do not spread.
Unplug in the event of
prolonged application
interruptions (over
60 minutes) and replace
screw cap.
Tightly sealing the
cartridge after use will
prolong the life of the
PUR hot-melt adhesive.
The load-bearing
capacity of the bond
will essentially depend
on the strength of the
substrate (e.g. when
glueing on wallpaper).
Loosening cartridge
screw cap
Mounting base station in a fixed position
If you wish, you can mount
the base station on a firm
base surface.
Two recessed holes are pro-
vided underneath the base
station for this purpose:
Spacing between screws
(2.9 mm dia.): 38 mm.
If you are unable to
remove the screw cap
with your bare hands
after several times of use
because it has become
stuck, it can be released
using the receptacle in
the base station (see
diagram).
Important: You must
first heat up the hot melt
adhesive in the base
station.
Always seal cartridge
firmly when heating and
after use.
Before heating a new
cartridge, allow heating
head to cool down.
If cartridge and heating
head accidentally stick
together, they can be
separated again after
they are warmed up.
Clean glue residue from
heating unit by mechani-
cal means.
GB
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Steinel PUR GLUE 50 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Steinel PUR GLUE 50 in the language / languages: All languages as an attachment in your email.

The manual is 1,52 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info