System Components
Package contents (Fig. 1.1)
Product dimensions (Fig. 1.2)
Product components (Fig. 1.3)
Group interconnection by means of communi-
cation cable (Fig. 1.9)
Installation height/reach (Fig. 2.0)
Manual override function (Fig. 2.1)
A. Wall mount panes
b. Light enclosure
C. IR sensor
D. Group interconnection cover tab
Installation (Fig. 1.4 – 1.8)
The site of installation should be at least 50 cm
away from another light because heat radiated
from it may activate the system. At minimum
reach (5 m), the light should be installed at a
height of no more than 1.8 m. To obtain the
specified reach of 12 m, the sensor should be
installed at a height of no more than 2.2 m.
Connecting the mains and load supply lead
(1.9)
The leads consist of three wires:
L = phase conductor (usually black or brown)
N = neutral conductor (usually blue)
PE = protective-earth conductor (green/yellow)
K = communication cable (optional)
If you are in any doubt, identify the conductors
using a voltage tester; then disconnect from the
power supply again. Connect phase (L), neutral
conductor (N) to the terminal block. Mixing up
the connections will produce a short circuit later
on in the product or your fuse box. In this case,
you must identify the individual cables and
re-connect them. Insulate protective-earth con-
ductor (PE) and simply place it next to terminal
block.
Note: A mains switch for switching ON and OFF
may, of course, be installed in the mains supply
lead. A mains switch is required for the manual
override function (Fig. 2.1, see Manual override
function)
Group interconnection (Fig. 1.9)
Communication cable K permits internal
STEINEL group interconnection of L 900 LED
and L 910 LED. For this, the cover tab (F) in the
terminal compartment must be broken out at
the point marked (K). As many as 10 lights
can be interconnected with each other. The
communication cable must not be longer
than 50 m.
Note:
- No voltage must be connected to the com-
munication cable. No external loads must be
connected!
- Within the interconnected group, all lights
operate in line with their specific DIP-switch
settings.
- Group interconnection is not possible in test
mode.
Functions (Fig. 1.7)
Once installed, the sensor can be put into
operation. All pre-programmed functions are
selected at DIP switches 1-6. Factory setting:
DIP switches OFF
DIP 1 effect lighting
OFF = Sensor mode, main light/soft start
ON = effect lighting as from light-level setting
selected, main light activated by sensor
DIP 2 night economy mode, effect lighting
OFF = effect lighting ON all night
ON = effect lighting ON for half the night in
relation to setting selected at DIP 1
DIP 3 twilight setting (response threshold)
OFF = 20 lux
ON = 2 lux
DIP 4 time setting (switch-OFF delay)
OFF = 2 min
ON = 15 min
DIP 5 test mode
OFF = test mode deactivated
ON = test mode activated (5 sec)
Note:
Communication (optional group interconnec-
tion) to the interconnected lights is deactivated
in test mode. Only the light being tested is in
test mode. The other lights remain in group
mode
DIP 6 Reach setting (sensitivity)
OFF = 12 m
ON = 5 m
Manual override function (Fig. 2.1)
If a mains switch is installed in the mains sup-
ply lead, the following functions are provided
in addition to simply switching light ON and
OFF:
Manual override
1) Activate manual override:
Turn switch OFF and ON twice. The light is set
to manual override for 4 hours. Then it returns
automatically to sensor mode.
2) Deactivate manual override:
Switch OFF and ON once. Light goes out or
switches to sensor mode.
Important:
The switch should be actuated in rapid
succession (in the 0.2–1 sec. range).
Note:
When groups are interconnected, this
command is sent to all of the lights that
are connected.
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Steinel L910 LED at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Steinel L910 LED in the language / languages: All languages as an attachment in your email.

The manual is 1,31 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info