Technical specifications
Output: max. 60 W / E 27
Power supply: 230 – 240 V/50 – 60 Hz
Power consumption: 0.8 W
Detection angle of sensor: 180° with sneak-by guard
Pivoting range of the sensor: 70° vertically
Sensor reach (dependent on the sensor setting,
ambient temperature and direction of approach): 12 m max.
Time setting: 8 sec. – 35 min.
Twilight setting: 2 – 2000 lux
IP rating, splashproof: IP 44
Protection class: II
Temperature range: - 20 °C to + 60 °C
Troubleshooting
SensorLight without power
n Fuse has blown; not switched
ON; break in wiring
n Short circuit
n Replace fuse; switch ON mains
switch; check wiring with
voltage tester
n Check connections
SensorLight does not switch ON
n Twilight setting in nighttime
mode during daytime operation
n Bulb burnt out
n Power switch OFF
n Fuse blown
n Detection zone not correctly
adjusted
n Adjust setting
n Replace light bulb
n Switch ON
n Replace fuse, check connection
if necessary
n Readjust
SensorLight does not switch OFF
n Continued movement within the
detection zone
n Check zone and readjust if
necessary or apply shroud
SensorLight switches ON when
it should not
n Wind is moving trees and bush-
es in the detection zone
n Cars in the street are detected
n Sudden temperature changes
due to weather (wind, rain,
snow) or exhaust air from fans or
open windows
n Adjust zone or apply shrouds
n Change detection zone,
tilt sensor down
n Adjust detection zone or install
in a different place
Change in SensorLight reach
n Differing ambient temperatures n When it is cold, shorten reach
by tilting sensor down
n When it is hot, tilt sensor up
Malfunction Cause Remedy
SensorLight does not switch
ON/OFF
n Animals moving in detection
zone
n Tilt sensor higher or apply
specific shrouds; adjust zone,
or apply shrouds
- 7 -
Installation
L=phase conductor
(mostly black, brown or grey)
N = neutral conductor (usually blue)
PE = protective-earth conductor, if present
(green/yellow)
Important: Loop the protective-earth conductor
through if necessary. A mains power switch for turning
the unit ON and OFF may of course be installed in the
mains supply lead. Important: Reversing the connec-
tions may result in damage to the unit. Please note
that the circuit must be protected by a 10 A circuit
breaker. Minimum installation height: 1.70 m.
Note on Fig. 4:
The light arm must be engaged in the bracket to
protect the internal wires from strain.
Function
햺
Time setting
The SensorLight stays ON for 8 sec. – 35 min.
(factory setting 8 sec.)
Twilight setting
Response threshold 2–2000 lux,
2 lux = twilight operation,
2000 lux = daylight operation (factory setting).
Safety instructions
Disconnect the power supply before performing any
work on the SensorLight!
During installation, the electric power cable to be
connected must be voltage-free. Therefore, switch
off the power first and check freedom from voltage
with a voltage tester.
Installation of the SensorLight involves work on the
mains power supply; it must therefore be performed
correctly according to applicable national installa-
tion regulations and electrical operating conditions.
(
D
- VDE 0100,
A
- ÖVE-ÖNORM E8001-1,
- SEV 1000)
Principle
Lights, alarms, and many other things triggered by
movement - for your convenience and safety. The
integrated pyroelectric infrared detector senses the
invisible heat radiated from moving objects (people,
animals, etc.). Detected in this way, the radiated heat
is converted electronically and switches the light ON.
Heat is not detected through obstacles, such as walls
or panes of glass. Heat radiation of this type will,
therefore, not trigger the sensor.
Reach setting
햹
A wide tilting range of 70° allows you to select a reach
of 2 – 12 m.
Adjustment
햻
Important: The most reliable way of detecting motion
is to install the SensorLight with the sensor aimed
across the direction in which a person would walk and
by ensuring that no obstacles (such as trees and walls,
for example) obstruct the line of sensor vision. Reach
is limited when walking directly towards the light.
Operation
If the SensorLight is to be switched ON independent-
ly from a source of heat in the detection zone, briefly
operate the indoor mains switch once. The SensorLight
is subsequently activated for the set time. Weather
can affect operation of the SensorLight. Strong gusts
of wind, snow, rain, hail may cause switching errors
because the unit cannot distinguish sudden changes
in temperature from heat sources. The multi-lens
(detector lens) can be cleaned if dirty with a damp
cloth (without cleaning products).
Declaration of conformity
This product complies with
- Low Voltage Directive 2006/95/EC
- EMC Directive 2004/108/EC
- RoHS Directive 2011/65/EC
- WEEE Directive 2012/19/EC
Functional Warranty
This STEINEL product has been manufactured with
great care, tested for proper operation and safety in
accordance with applicable regulations and then
subjected to random sample inspection. STEINEL
guarantees that it is perfect condition and proper
working order. The warranty period is 36 months,
starting from the date of sale to the consumer.
We will remedy defects caused by material flaws or
manufacturing faults. The warranty will be met by
repair or replacement of defective parts at our own
discretion. The warranty does not cover damage to
wear parts, nor does it cover damage or defects
caused by improper treatment, maintenance or the
use on non-genuine parts. Further consequential
damage to other objects shall be excluded. The
warranty will only be honoured if the product is sent
to the appropriate Service Centre fully assembled
and well packed with a brief description of the fault,
receipt or invoice (date of purchase and dealer's
stamp).
Service:
Please ask your nearest service
centre how to proceed for repairing
faults not covered by the warranty or
occurring after the warranty expires.
- 6 -
GB