15
Malfunction Cause Remedy
Without power ■ Fuse faulty,
not switched ON
■ Short circuit
■ New fuse, switch ON
mains switch, check lead
with a voltage detector
■ Check connections
Does not switch ON ■ Twilight setting in
night-time mode during
daytime operation
■ Bulb faulty
■ Power switch OFF
■ Fuse faulty
■ Detection zone not targeted
■ Adjust setting
■ Replace light bulbs
■ Switch ON
■ New fuse, check
connection if necessary
■ Re-adjust
Does not switch OFF ■ Continued movement in
the detection zone
■ Light is in detection zone
and keeps switching ON
as a result of temperature
change
■ Check zone and re-adjust
or shroud if necessary
■ Change zone, or apply
shroud
Keeps switching ON/OFF ■ Lamp being operated
in the detection zone
■ Animals moving in the
detection zone
■ Adjust zone, shroud or
increase distance
■ Adjust zone, or apply
shroud
Switches ON when it
should not
■ Wind moves trees and
bushes in the detection
zone
■ Cars in the street are
being detected
■ Sudden change in temp-
erature due to weather
(wind, rain, snow) or air
expelled from fans, open
windows
■ Adjust zone or
apply shroud
■ Adjust zone or
apply shroud
■ Adjust zone, change
installation site
LED flashes rapidly ■ Overload protection
activated
■ Switch OFF unit and
switch ON again after
cooling down
Troubleshooting
14
Sensor operation
1) Switch light ON (when light is OFF):
Turn switch OFF and ON once.
Light stays ON for the period selected.
2) Switch light OFF (when light is ON):
Turn switch OFF and ON once.
The light goes out or switches over to
sensor mode.
Manual override function
Manual override
1) Activate manual override:
Turn switch OFF and ON twice. The lamp is
set to stay on for 4 hours (red LED lights up
behind the lens). Then it returns automatically
to sensor mode (red LED off).
2) Deactivate manual override:
Turn switch OFF and ON once. The light goes
out or switches over to sensor mode.
If a mains switch is installed in the mains supply
lead, the light is capable of the following func-
tions in addition to the simple ON/OFF function:
Important: The switch should be operated
several times in rapid succession.
Technical specifications
Dimensions (H x Ø): 82 x 51 mm
Output: max. 1000 W (filament bulbs)*
max. 5 AX (fluorescent lamps)*
Switching capacity: 50 – 240 V~ / 5 A
Connection: 230 – 240 V/50 Hz
Angle of coverage: 360° with 180° angle of aperture
Reach: 8 m max. all round
Sensor system: 10 detection zones, 720 switching zones
Time setting: 5 sec. – 20 min.
Twilight setting: 2 – 2000 lux
Manual override: 4 hrs. selectable
Enclosure (top/bottom): IP 20
Temperature range: -20 °C to +50 °C
*VDE tested
Reach setting / adjustment
With an assumed mounting height of 2.5 m,
the maximum reach of the sensor is 8 m. The
detection zone can be optimally adjusted ac-
cording to needs. The shroud provided can be
used for masking out any number of lens seg-
ments to shorten reach as required. This pre-
vents the light from being activated uninten-
tionally, e.g. by cars, passers-by etc. and
allows you to target danger spots. The shroud
can be separated along the pre-grooved div-
isions in the vertical and horizontal directions
and applied to the lens.
GB