– 12 – – 13 –
Safety warnings
Disconnect the power
before attempting any
work on the motion
detector.
The electrical connec-
tion lead must be dead
during installation.
Therefore, switch off the
power supply fi rst and
check that the circuit is
disconnected using a
voltage tester.
Installation of the sensor
involves work on the
mains power supply.
This work must therefore
be carried out profes-
sionally in accordance
with the applicable wiring
regulations and supply
conditions.
Please note that the sen-
sor must be protected
by a 10 A circuit breaker.
The mains supply lead
must be no greater than
10 mm in diameter.
Only carry out time and
light threshold settings
with the lens fi tted.
Principle
The IS 2180-2 is equipped
with two 120° pyro sensors
which detect the invisible
heat emitted by moving
objects (people, animals
etc.). The heat detected
is electronically converted
into a signal that switches
on loads (e.g. a light) con-
nected to it. Heat is not
detected through obstacles,
such as walls or panes of
glass. Heat radiation of this
type will, therefore, not trig-
ger the sensor. With a 90°
angle of aperture, the two
pyro sensors cover a detec-
tion angle of 180°. The lens
can be removed and turned,
thereby permitting two max.
basic reach settings of 5m
or 12 m. Using the wall
mounts provided with the
unit, the infrared sensor can
easily be fi tted to internal
and external corners.
Important: The most
reliable way of detecting
motion is to install the unit
so that the sensor is aimed
across the direction in
which a person would walk
and by ensuring that no
obstacles (such as trees,
walls etc.) obstruct the line
of sensor vision.
Reach max. 12 m Reach max. 5 m
Direction of approach:
towards the sensor
Direction of approach:
across the detection zone
Installation instructions
Dear Customer,
Congratulations on purchas-
ing this STEINEL Infrared
Sensor and thank you for
the confi dence you have
shown in us. You have cho-
sen a high-quality product
that has been manufac-
tured, tested and packed
with the greatest care.
Please familiarise yourself
with these instructions
before attempting to install
the sensor since prolonged
reliable and trouble-free op-
eration will only be ensured
if it is installed properly.
We hope your new Infrared
Sensor will give you lasting
satisfaction.
System components
Security screw
Front cover
Lens (can be removed
and turned for selecting
the max. basic reach set-
tings of 5 m or 12 m)
Light threshold setting
control 2 – 2000 lux
Time setting control
10 sec. – 15 min.
Clip (housing can be
ipped up for assembly
and connection to mains
power supply)
Dimensions: (H x W x D) 120 x 76 x 56 mm
Output:
Filament bulbs, 1000 W max., operating on 230 V AC
Fluorescent lamp, 500 W max., at cos ϕ = 0.5,
inductive load at 230 V AC
6 x 58 W each max., C ≤ 132 μF
operating on 230 V AC
*1)
Connection: 230 – 240 V, 50 Hz
Detection angle 180° horizontal, 90° vertical
Sensor reach: basic setting 1: 5 m max.
basic setting 2: 12 m max. (factory setting)
+ precision adjustment from 1 – 12 m by means
of clip-on shrouds
Time setting: 10 sec. – 15 min. (factory setting: 10 sec.)
Light threshold: 2 – 2000 lux (factory setting: 2000 lux)
Enclosure: IP 54
*1)
Fluorescent lamps, low-energy bulbs, LED lights with electronic ballast (total capacity of all connected
ballasts below the value specifi ed).
Technical specifi cations
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Steinel IS 2180-2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Steinel IS 2180-2 in the language / languages: All languages as an attachment in your email.

The manual is 3,45 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info