592416
7
Zoom out
Zoom in
Previous page
1/47
Next page
ca.12 m
Disconnect the power
supply before any work
on the motion detector!
During installation, the
electric power cable to
be connected must be
voltage-free. There-
fore, switch off the power
first and check freedom
from voltage with a
voltage tester.
Installation of the sensor
involves work on the
mains power supply; this
work must therefore be
carried out professionally
in accordance with regu-
lations.
Please note that the
sensor must be protected
by a 10 A circuit breaker.
The mains supply lead
must be no greater than
10 mm in diameter.
Perform time and twilight
adjustment only with the
lens installed.
Safety notification
Principle
Important: The most reli-
able motion detection is
achieved by mounting the
unit diagonally to the direc-
tion of movement and en-
suring that no obstacles
(such as trees or walls)
obstruct the line of sight.
Max. reach 12 m Max. reach 5 m
Walking direction: frontal Walking direction: diagonal
The detector is equipped
with two 120° pyro sensors
which detect the invisible
infrared heat emitted by
moving objects (pedes-
trians, animals, etc.). The
heat thus detected is elec-
tronically converted and
switches on connected
consumers (e.g. a light).
No heat radiation is detect-
ed through obstacles, such
as walls or glass and no
switching therefore occurs.
With the aid of the two pyro
sensors, a detection angle
of 180° (with an opening
angle of 90°) is achieved.
The lens is removable and
can be rotated. This allows
two basic reach settings of
max. 5 m or 12 m. The
infrared sensor can be
installed without difficulty
on inside and outside cor-
ners using the enclosed
wall mounts.
Dimensions: (H x W x D) 120 x 76 x 56 mm
Output: max. 1000 W (ohmic load, e.g. filament bulb)
max. 1500 W (uncorrected, inductive, cos ϕ = 0.5,
e.g. fluorescent lamps)
max. 1600 W (electronic ballasts, capacitive;
e.g. energy-saving lights, max. 8)
Connection: 230–240 V, 50 Hz
Angle of coverage: 180° horizontal, 90° vertical
Sensor reach: basic setting 1: max. 5 m
basic setting 2: max. 12 m
+ fine adjustment with shrouds: 1–12 m
Time setting: 10 sec.–15 min.
Twilight setting: 2–2000 lux
Enclosure: IP 54
Installation instructions
Appliance description
Dear customer,
Thank you for the confi-
dence that you have placed
in us in purchasing your
new STEINEL infrared sen-
sor. You have decided on a
high quality product, manu-
factured, tested and pack-
ed with the greatest care.
Please familiarise yourself
with these instructions
before installation, since
only correct and commis-
sioning guarantees long,
reliable and trouble-free
operation.
We hope you enjoy your
new usage appliance.
Safety screw
Decorative cover
Lens (removable and
rotatable to select the
reach – basic setting of
max. 5 m or 12 m
Twilight setting
2–2000 lux
Time setting
10 sec.–15 min.
Catch (housing can be
swung open for installa-
tion and power supply
connection)
Technical specifications
GB
12 13
Serie_180_10spr.qxd 18.10.2004 15:50 Uhr Seite 13
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Steinel IS 180 Serie at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Steinel IS 180 Serie in the language / languages: English, German, Dutch, Danish, French, Italian, Swedish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 1,55 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info