Electrical installation/Automatic mode
In selecting the wiring leads, it
is important to meet the wiring
regulations laid down in VDE
0100 (see Safety warnings on
page 20). The following applies
to wiring presence detectors
:
Section 6 of VDE 0100 520 per-
mits the use of a multiple-
conductor cable containing
both the mains-voltage wires
as well as the control lines (e.g.
NYM5x1.52) for the wiring
bet-
ween sensor and electronic bal-
last. The mains supply lead must
be no greater than 10 mm in dia-
meter. The clamping range of
the mains terminal is designed
for a maximum of 2
x 2.5 mm
2
.
When installing the surface-
mounting version, connect a
circuit breaker (16 A) on the
line side.
PSN
LL'
L
N
P
L
N
COM1
PSN
LL'
L
N
L
N
1-10V
1-10V
+
max. 100 mA
DIM
DIMCOM 1 COM 2
L
N
P
L
N
PSNLL' PN
COM 1 AP
23


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Steinel IR Quattro HD at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Steinel IR Quattro HD in the language / languages: All languages as an attachment in your email.

The manual is 4,58 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info