Functions
Contact-free switching
Move your hand in front of
the sensor unit at a dis-
tance of max. 5 cm and the
connected light will switch
on.The procedure is equally
simple when switching off.
Orientation light
The Sensor Switch
NF 50 UP is equipped with
a red LED. This serves as
an orientation light in the
dark, so that the switch is
easier to find.
Note:
Parallel switching or ex-
change of an existing two-
way circuit is not possible.
(only for NF 50 UP)
Technical specifications
IR 180 UP: NF 50 UP:HF 360 UP:
Note for IR 180 UP:
The installation position
should be at least 1 m from
a light, since heat radiation
may trigger the system.
Installation procedure:
1. Pull the mains lead out
of the flush box and strip
the insulation from the
individual leads.
Connecting the supply
lead (refer to Ill. on
page 5)
The mains lead consists of
a 3 phase cable.
L = phase conductor
(usually black or
brown)
N = neutral conductor
(usually blue)
L‘ = phase conductor
(usually black or
brown)
If in doubt, the cable must
be identified with a voltage
tester. Switch off the current
again. Phases (L) and (L‘)
in addition to the neutral
conductor (N) are connec-
ted to the terminal block. A
protective-earth conductor
is not required.
Important: Reversing the
connections may result in
damage to the unit.
2. Push the basic elem-
ent into the flush box
and arrange horizon-
tally. Take care that the
cables are not pinched.
Tighten both screws on
the expansion claw until
the basic element is firm-
ly seated or screw with
socket fixing screws on
the support ring.
3. Apply the cover frame
and surround and
carefully mount the sen-
sor unit without tilting.
4. Once the mains connec-
tion has been made, the
sensor switch can be
operated (refer to Func-
tions section).
Only IR 180 UP and
HF 360 UP:
The adjustment controls for
the functions are concealed
behind the folding design
shade. Push in the catch on
the sensor unit with a screw-
driver and fold the design
shade forwards.
Note:
Parallel switching of
IR 180 UP and HF 360 UP
is possible. Nevertheless, a
neutral lead must be pres-
ent on each flush box. The
max. output to be switched
does not increase as a re-
sult.
* Installation above a door
(IR 180 UP / HF 360 UP / NF 50 UP)
Dimensions:
Output:
Connection:
Contact gap:
Installation height:
Sensor technology:
Transmission output:
Angle of coverage:
Reach:
Twilight setting:
Time setting:
Permanent light:
Permanent light OFF:
Orientation light:
(H x W x D) 80 x 80 x 55 mm
max. 1000 W (ohmic load, e.g. filament bulb)
max. 500 VA (uncompensated, inductive, cos ϕ = 0.5
e.g. fluorescent lamps )
230 V, 50 Hz
3-lead connection (L, L’, N)
µ, contact clearance of less than 1.2 mm between the
contacts when unit is switched off.
approx. 1.1 + 2.2 m*
Infrared sensor
-
180° with 90° angle
of aperture
max. 8 m
2 - 2000 lux
10 sec. - 30 min.
switchable (4 h)
switchable
-
approx. 1.1 + 2.2 m*
5.8 Ghz
High frequency
approx. 1 mW
360° with 140° angle
of aperture
1 - 8 m
continously adjustable
2 - 2000 lux
10 sec. - 30 min.
switchable (4 h)
switchable
-
approx. 1.1 m
5.8 Ghz
High frequency
approx. 1 mW
-
approx. 5 cm
-
-
-
-
red LED
16
Installation
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Steinel IR 180 UP at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Steinel IR 180 UP in the language / languages: All languages as an attachment in your email.

The manual is 1,38 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info