Instructions for the installer
75
+
3.8 Gas adjustments
The injectors not supplied with the appliance should be requested from the Service Centre.
If the cooking appliance is set up for a different type of gas than that available, its injectors must be
replaced, the minimum flow regulated and the rubber-holder changed. In order to replace the
injectors in the cooking hob, it is necessary to carry out the following operations:
For cooktops, the Data Label is located on the underside of the appliance. A duplicate label is
supplied to adhere in an accessible area adjacent to the appliance. For cookers, the label is
situated in the appliance drawer. This appliance is suitable for Natural Gas and Propane; ensure
that the available gas supply matches the Data Label.
If the cooking appliance is set up for a different type of gas than that available, its injectors must be
replaced, the minimum flow regulated and the rubber-holder changed. In order to replace the
injectors in the cooking hob, it is necessary to carry out the following operations:
remove the pan supports;
remove the burners and burner caps (Fig. A);
take out the injector (Fig. B) and replace it with one
suitable for the new type of gas (see "G
ENERAL
INJECTORS TABLE
" on page 76-77);
replace the gas label (on the rear of the appliance) with
the new one provided with the injectors kit;
refit all parts by following the disassembly instructions in
reverse order and taking care to position the burner cap
correctly on the burner.
3.8.1 Minimum flow of valved cooking hob taps
Switch on the burner and turn the control
knob towards the minimum flow position ;
remove the knob;
using a screwdriver, adjust the internal screw
Z until the correct low flame is obtained;
refit the knob.
Unscrew the adjustment screw Z to increase the flow, or tighten it to reduce the flow.
The adjustment is correct when the low flame measures approximately 3 or 4 mm.
For butane/propane, the adjustment screw should be tightened all the way.
When changing quickly from maximum to minimum flow and vice versa make sure that the
flame does not go out.
3.9 Connecting to LPG
Gas may only be connected to a gas installation, whether bottle supplied or other.
Gas may only be connected to a gas installation, whether bottle supplied or other.
When converting from Natural Gas to Propane ensure that the NG regulator is removed and
replaced with the Test Point Assembly. A gas regulator suitable for a supply pressure of 2.75kPa
should be part of the gas tank supply and should be adjusted with the Wok burner operating at
maximum. Replace the old data plate with one which is suitable for the type of gas for which the
appliance has been regulated.
75


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Steel Cucine PARTY at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Steel Cucine PARTY in the language / languages: English, German, French, Italian as an attachment in your email.

The manual is 4,64 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info