IMPORTANT FOR FRANCE:
If the product is wall mounted, the electrical connection must be made according to the enclosed
drawing, cutting the cable and using a connection block between the product cable and the electricity
supply.
In humid rooms, bathrooms or kitchens, this connection block must be installed at least 25 cm from
the floor. The electrical connection must also include the use of a 2-pole switch with a contact opening
distance of at least 3 mm.
5. Cable storage
While the product is not in use, you can store the cable pushing it into the base of the product.
Note that while the product is in operation, the cable must always be completely pulled out.
6. Use of the heater
See picture 5
6.1 Version with switch and thermostat
The heater has 2 knobs controlling the switch and the thermostat.
The switch knob has 5 positions, allowing to select the desired power setting.
Starting from the “¿ position, turn the thermostat knob clockwise until you hear a "click”: the
appliance starts working at the desired power setting.
The thermostat maintains the desired room temperature switching on and off automatically the
appliance. The more the knob is turned clockwise, the higher is the maintained temperature.
Maximum thermostat setting corresponds at about 30°C; ¿position corresponds to approximately
5°C.
For correct use of the thermostat , see section “ USE OF THE THERMOSTAT”
6.2 Model with thermostat and 60' timer
The heater has 2 knobs.
Turn the timer knob clockwise to select the working time you prefer from 5 to 60'. The heater starts
working at full power (2000W) and thermostat setting doesn’t influence the functioning;
After the selected period the heater will automatically turn to mid power (1000W), thermostatically
controlled according to the thermostat setting. For the use of the thermostat see section 6.3.
When the heater is working under timer control at full power, the thermostat doesn't control the room
temperature. In this condition, do not use the heater in small rooms when they are occupied by
persons not capable of leaving the room on their own, unless constant supervision is provided.
6.3 Use of the thermostat
In a room where the temperature is too high (more than 30°C), it is normal that the thermostat will not
switch on the heater.
In a room where the temperature is too low (around 5°C or even less) it is also normal that the
thermostat will keep the appliance working until the temperature gets higher.
To select the right thermostat position we suggest you to
- turn the thermostat in maximum position (clockwise);
- leave the appliance working until the comfortable temperature is reached;
- turn the knob anti clockwise until you hear a "click" and the appliance stops;
- turn clockwise again the knob (just a little): in this position the thermostat will maintain the
comfortable temperature you have selected.
7. Safety in the event of the product not functioning normally
In the event of overheating, the safety system will automatically turn off the heating elements and the
motor. If this happens:
- switch off the fan heater using the main switch;
- remove the cause of overheating (i.e. obstacles in front of the air inlet or air outlet grilles, unusual
accumulations of dirt, etc);
- let the heater cool down for 15/20 minutes;
- switch on the fan heater and check it is functioning properly.
L If you notice irregular operation, damage to the heating element or to the structure of the appliance,
disconnect the product from the mains power supply and contact your technical assistance center or dealer.
8. Maintenance
This heater does not require any particular maintenance.
We recommend you clean the air inlet and air outlet grilles at least twice a year with a vacuum
cleaner, to remove dust from the motor and the heating elements.
If the heater needs to be repaired, please contact an authorized center.
If the cable is to be changed, please remember that a 2x1m
2
H05VV-F <HAR> cable must be used.
L
N
Electrical
t
it
Phase = brown
Neutral = blue
Product’s
bl
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Steba Pikkolo 60 T 3 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Steba Pikkolo 60 T 3 in the language / languages: English, German, Dutch, French, Italian as an attachment in your email.

The manual is 1,52 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info