34
STAR TRAC E SERIES BIKES O
WNER’S GUIDE
Lowest Highest Default
Item Value Value Value Meaning
Time 5 99 20 Maximum time in minutes allowed for program, excluding warm-up and cool-
down.
Weight 50 (Lb) 350 (Lb) 155 lbs Default (to user), typical weight in lb (UNITS=English), or kg
22 (KG) 158 (KG) 70 (KG) (UNITS=Metric).
Language N/A N/A English Language in English, Dutch, French, German, Portuguese, Spanish, Swedish,
Italian or Katakana.
Model N/A N/A BIKE BIKE = Upright or Recumbent Bikes
TBT = Total Body Trainer
STEPPER = Stepper
LCB Type VER1 VER3 VER2 Type of LCB detected by display.
CSAFE OFF ON OFF Turns on/off CSAFE communication.
PVS N/A N/A ATSC ATSC/NTSC or PAL/SECAM, RF Signal for PVS
WALL POWER OFF ON OFF Turns the wall power setting on/off.
AUTO FAN OFF ON ON Turns Fan on 1 minute into program
OPER Hours 0 65535 0 Total operating hours
BATT Hours 0 65535 0 Total battery use hours
Quick Start 0 65535 0 Number of times the Quick Start program was run since last reset.
Manual 0 65535 0 Number of times the Manual Program was run since last reset.
Warm Up 0 65535 0 Number of times the Warm Up Program was run since last reset.
Auto Pilot 0 65535 0 Number of times the Auto Pilot Program was run since last reset.
IHR Program 0 65535 0 Number of times the Interval Heart Rate Control Program was run since last
reset.
CHR Program 0 65535 0 Number of times the Constant Heart Rate Control Program was run since last
reset.
WI Program 0 65535 0 Number of times the Watts Interval Program was run since last reset.
CW Program 0 65535 0 Number of times the Continuous Watts Program was run since last reset.
Fit Test 0 65535 0 Number of times the Fitness Test Program was run since last reset.
Alpine 0 65535 0 Number of times the Alpine Pass Program was run since last reset.
Rndm Prog 0 65535 0 Number of times the Random Hill Program was run since last reset.
Comm Lost 0 65535 0 Number of times a “Communication Lost” condition occurred since last reset.
Key Down 0 65535 0 Number of times a “Key Down” condition occurred since last reset.
BATT LOW 0 65535 0 Number of times battery voltage measured between 5.3 and 5.7 volts
REPL BATT 0 65535 0 Number of times battery voltage measured below 5.3 volts
LED Test N/A N/A N/A Access to integral LED test function (for use by authorized Maintenance
Technician).
Keypad Test N/A N/A N/A Access to integral keypad test function (for use by authorized Maintenance
Technician).
Heart Rate N/A N/A N/A Access to integral heart rate system test function (for use by authorized
Test Maintenance Technician).