VDE- and DIN provisions. Only use connecting cables
with the H 07 RN designation.
Keeping a copy of the type designation on the connect-
ing cable is a specication
Dmaged electric connecting cables
Insulation damages frequently occur on electric connect-
ing cables. The reasons are:
Pressure points, if connecting cables are routed
through window or door gaps.
Kinks due to improper mounting or routing of con-
necting cables.
Intersections due to overruns of connecting cables.
Insulation damage due to pulling out from wall sock-
ets.
Cracks due to ageing of insulation.
Such damaged electric connecting cables should not be
used and can be fatal because of the insulation damage
AC motor 230 V/ 50 Hz
Mains voltage 230 Volt / 50 Hz.
Mains connection and extension cable must have
3-wires = P + N + SL. - (1/N/PE).
Extension cables must have a minimum cross-section of
1.5 mm².
The mains connection is secured with a max. 16A fuse.
Maintenance
Caution! Pull out power plug.
Clean the machine after each work cycle.
Replace worn out cutting discs.
Replace damaged protection device
Dust and pollution must be removed regularly from the
machine. The best way to clean the machine is with a
piece of cloth or brush.
All moveable parts must be re-lubricated at periodic
intervals.
Do not use any corrosive substances to clean the
plastic. A damp cloth is sufcient in most cases.
The tub (4) and coolant pump (13) must be cleaned
regularly to remove dirt, as otherwise the pump or the
pipe or the cooling of the diamond cutting disc (10) is
not guaranteed.
Service information
Please note that the following parts of this product are
subject to normal or natural wear and that the following
parts are therefore also required for use as consuma-
bles.
Wear parts*: Saw blade, carbon brush, table & cutting
head guides
* Not necessarily included in the scope of delivery!
Spare-part ordering
Please quote the following in your order for spare parts:
Type of device
Article No. of device
Ident. No. of device
Spare Part No. of the required spare part
Start-up of the leakage current circuit-breaker:
The function should be checked before each start-up
and at regular Intervals (min. once every week).
If the leakage current circuit-breaker does
not switch off properly during this test, there
is no personal protection! The device must
therefore be switched off immediately!
In case of damages caused by the non-observation of
this operating instructions manual, all warranty claims
will become null and void. We do not accept any liabil-
ity for consequential damages.
Check the product for damage before each use! If you
detect a damage, do not connect the product to the
mains power supply!
After actuating the orange Reset button, the device
is ready for operation. Before operation, please test
the triggering with the help of the Test button (as de-
scribed in “Operation”).
Insert the leakage current circuit-breaker into the
socket.
Press the orange Reset button.
A red symbol is displayed in the window indicating op-
erational readiness.
Press the red Test button. This action simulates a
leakage current.
If the machine is working properly, the circuit-breaker
will disconnect the load from the mains. This is dis-
played in the window through the disappearance of
the red symbol.
Protection of man and animal is effective only if the
machine works properly.
The Reset button must be pressed a second time for
operation.
The load can now be inserted.
Technical data:
Triggering leakage current: < 30 mA
Power supply: 230V~/50Hz
Load capacity: 16A (3680W)
Number of pins: 2-pin wired
Preliminary fuse: 16 A
Protection type: IP54
Dimensions: 126x50x88mm
USE ACCORDING TO MANUFACTURER‘S INSTRUC-
TIONS!
The portable leakage current circuit-breaker is designed
for wet grinding machines and similar electrical loads in
the household.
It is simply connected between the mains power supply
and the load, and therefore offers optimum protection
against physical contact with live components and sud-
den restart of the machine after restoration of power.
Always operate the machine with the provided leakage
current circuit-breaker installed.
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Starkwerk SW 4700 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Starkwerk SW 4700 in the language / languages: English, German as an attachment in your email.

The manual is 4.07 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info