622250
13
Zoom out
Zoom in
Previous page
1/208
Next page
13
77-322
Horizontal Beam Accuracy
(See fi gure
M
)
M
1
Place laser tool as shown with horizontal, vertical, and
both left and right vertical laser beams ON. Mark point P
1
where the horizontal and left vertical laser beams cross.
M
2
Rotate laser tool 90° and align front vertical laser beam
with point P
1
. Mark point P
2
where the horizontal and front
vertical laser beams cross.
M
3
Rotate laser tool 90° and align right vertical laser beam
with point P
1
. Mark point P
3
where the horizontal and right
vertical laser beams cross.
M
4
Measure the vertical distance D
2
between the highest
and lowest point.
Calculate the maximum offset distance and compare to D
2
.
• If D
2
is not less than or equal to the calculated
maximum offset distance the tool must be returned to
your Stanley Distributor for calibration.
Maximum Offset Distance:
= 0,26
mm
m
x D
1
m
Maximum
= 0,0032
in
ft
x D
1
ft
Compare: (See fi gure
M
4
)
D
2
≤ Maximum
Example:
• D
1
= 5 m, D
2
= 0,65 mm
• 0,26
mm
m
x 5 m = 1,3 mm (maximum offset distance)
0,65 mm ≤ 1,3 mm (TRUE, tool is within calibration)
Vertical Beam Accuracy
(See fi gure
N
)
N
1
Measure the height of a door jamb or reference point to
get distance D
1
. Place laser tool as shown with laser ON.
Aim vertical beam towards door jamb or reference point.
Mark points P
1
, P
2
, and P
3
as shown.
N
2
Move laser tool to opposite side of door jamb or
reference point and align the same vertical beam with
P
2
and P
3
.
N
3
Measure the horizontal distances between P
1
and the
vertical beam from the 2nd location.
Calculate the maximum offset distance and compare to D
2
.
• If D
2
is not less than or equal to the calculated
maximum offset distance the tool must be returned to
your Stanley Distributor for calibration.
Repeat the above steps to check the other beams.
Maximum Offset Distance:
= 0,26
mm
m
x D
1
m
Maximum
= 0,0031
in
ft
x D
1
ft
Compare: (See fi gure
N
3
)
D
2
≤ Maximum
Example:
• D
1
= 2 m, D
2
= 0,3 mm
• 0,26
mm
m
x 2 m = 0,52 mm (maximum offset distance)
0,3 mm ≤ 0,52 mm (TRUE, tool is within calibration)
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Stanley SML 77-322 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Stanley SML 77-322 in the language / languages: All languages as an attachment in your email.

The manual is 3,14 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info