720421
6
Zoom out
Zoom in
Previous page
1/96
Next page
6
ENGLISH
(Original instructions)
To select forward rotation, push the forward/reverse slider
(3) to the left.
To select reverse rotation, push the forward/reverse slider
to the right.
Warning! Never change the direction of rotation while the
motor is running.
Setting the drilling depth ( g. C)
Press in the depth lock button (8).
Set the depth stop (7) to the desired position. The maxi-
mum drilling depth is equal to the distance between the tip
of the drill bit and the front end of the depth stop.
Release the depth lock button.
Switching on and off
To switch the tool on, press the variable speed switch (1).
The tool speed depends on how far you press the switch.
As a general rule, use low speeds for large diameter drill
bits and high speeds for smaller diameter drill bits.
For continuous operation, press the lock-on button (2) and
release the variable speed switch. This option is available
only in forward (clockwise) rotation.
To switch the tool off, release the variable speed switch.
To switch the tool off when in continuous operation, press
the variable speed switch once more and release it.
Accessories
The performance of your tool depends on the accessory used.
Stanley Fat Max and Piranha accessories are engineered to
high quality standards and designed to enhance the perfor-
mance of your tool. By using these accessories you will get
the very best from your tool.
Maintenance
Your Stanley Fat Max corded/cordless appliance/tool has
been designed to operate over a long period of time with
a minimum of maintenance. Continuous satisfactory opera-
tion depends upon proper tool care and regular cleaning.
Warning! Before performing any maintenance on corded/
cordless power tools:
Switch off and unplug the appliance/tool.
Or switch off and remove the battery from the appliance/
tool if the appliance/tool has a separate battery pack.
Or run the battery down completely if it is integral and then
switch off.
Unplug the charger before cleaning it. Your charger does
not require any maintenance apart from regular cleaning.
Regularly clean the ventilation slots in your appliance/tool/
charger using a soft brush or dry cloth.
Regularly clean the motor housing using a damp cloth. Do
not use any abrasive or solvent-based cleaner.
Regularly open the chuck and tap it to remove any dust
from the interior (when tted).
Mains plug replacement (U.K. & Ireland only)
If a new mains plug needs to be tted:
Safely dispose of the old plug.
Connect the brown lead to the live terminal in the new
plug.
Connect the blue lead to the neutral terminal.
Warning! No connection is to be made to the earth terminal.
Follow the tting instructions supplied with good quality plugs.
Recommended fuse: 5 A.
Protecting the environment
Z
Separate collection. Products and batteries
marked with this symbol must not be disposed of
with normal household waste.
Products and batteries contain materials that can be recov-
ered or recycled reducing the demand for raw materials.
Please recycle electrical products and batteries according to
local provisions.
Further information is available at www.2helpU.com
Technical data
KFFMED500 (Type 1)
Input voltage V
AC
230
Power input W
750
No-load speed min
-1
0-1050
Impact rate min
-1
5,200
Impact energy per
stroke according to
EPTA-Procedure 05/2009
J
1.8
Max. drilling capacity
Concrete mm
26
Steel mm
13
Wood mm
30
Weight
kg
2.3
Level of sound pressure according to EN 60745:
Sound pressure (L
pA
) 90 dB(A), uncertainty (K) 3 dB(A)
Sound power (L
WA
) 101 dB(A), uncertainty (K) 3 dB(A)
Vibration total values (triax vector sum) according to EN 60745:
Hammer drilling into concrete (a
h, HD
) 16.3 m/s
2
, uncertainty (K) 1.5 m/s
2
Chiselling (a
h, Cheq
) 13.5 m/s
2
, uncertainty (K) 1.5 m/s
2
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Stanley KFFMED500 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Stanley KFFMED500 in the language / languages: All languages as an attachment in your email.

The manual is 8,27 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info