12.
If your measurement is greater than the Allowable
Distance Between P1 & P4 for the corresponding Vertical
Distance (D1) in the following table, the laser must be
serviced at an authorized service center.
Height of Vertical
Distance (D1)
Allowable Distance
Between P1 and P4
2.5m (8’) 1.5mm (1/16")
5m (16′) 3.0mm (1/8”)
6m (20’) 3.6mm (9/64”)
9m (30′) 5.5mm (9/32”)
Using the Laser
Operating Tips
Always mark the center of the beam created by the laser.
Extreme temperature changes may cause movement of
internal parts that can affect accuracy. Check your accuracy
often while working.
If the laser is ever dropped, check to make sure it is still
calibrated.
As long as the laser is properly calibrated, the laser is self-
leveling. Each laser is calibrated at the factory to nd level as
long as it is positioned on a at surface within average ± 4°
of level. No manual adjustments are required.
Use the laser on a smooth, at, level, surface.
Turning the Laser Off
Slide the Power/Transport Lock switch to the OFF/Locked
position (Figure
A
6
) when the laser is not in use. If the
switch is not placed in the Locked position, the laser will not
turn off.
Using the Laser with Accessories
WARNING:
Since accessories other than those offered by
Stanley have not been tested with this laser, use of
such accessories with this laser could be hazardous.
Only use Stanley accessories that are recommended for use
with this model. Accessories that may be suitable for one laser
may create a risk of injury when used with another laser.
The bottom of the laser is equipped with 1/4-20 and 5/8-11
female threads (Figure
C
) to accommodate current or future
Stanley accessories. Only use Stanley accessories specied
for use with this laser. Follow the directions included with the
accessory.
Recommended accessories for use with this laser are available
at extra cost from your local dealer or authorized service center.
If you need assistance locating any accessory, please contact
your nearest Stanley service center or visit our website:
http://www.2helpU.com.
Using the Laser with the Multibracket
Most line/dot lasers which have a 5/8-11 mounting thread can
be used with the Multibracket FMHT77435 (Figure
C
). The
multibracket can then be used free-standing or mounted in
several ways:
Use its rubber strap around a pole, 2”×4”, or other vertical
object.
Use its rear magnets against a metal beam.
Hook its rear screw hole over a nail or screw on a wall.
Use its ceiling clamp to hold onto the track for a hanging/
suspended ceiling.
Use the bottom 5/8-11 or 1/4-20 thread to attach to a tripod.
Maintenance
When the laser is not in use, clean the exterior parts with
a damp cloth, wipe the laser with a soft dry cloth to make
sure it is dry, and then store the laser in the kit box provided.
Although the laser exterior is solvent resistant, NEVER use
solvents to clean the laser.
Do not store the laser at temperatures below -20 ˚C (-5 ˚F) or
above 60 ˚C (140 ˚F).
To maintain the accuracy of your work, check the laser often
to make sure it is properly calibrated.
Calibration checks and other maintenance repairs may be
performed by Stanley service centers.
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Stanley FMHT77595 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Stanley FMHT77595 in the language / languages: All languages as an attachment in your email.

The manual is 15,43 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info