Protección de sobrecarga: Fusible 1: F 400 mA/690 V
Fusible 2: F 10 A/690 V
Corriente máxima de entrada: 10A (Para entradas > 2A: duración
de la medición < 10 segundos, intervalo >15 minutos)
Rango de frecuencia: 40 Hz ~ 400 Hz
Respuesta: Promedio, calibrada en rms de la onda sinusoidal
Caída máxima de tensión: 400 mV
Nota: El rango de 10 A se especifica del 20% al 100% del rango.
Frecuencia
Rango Resolución Exactitud
9.999 Hz 0.001 Hz ± (1.0% + 3)
99.99 Hz 0.01 Hz
± (0.8% + 3)
999.9 Hz 0.1 Hz
9.999 kHz 1 Hz
99.99 kHz 10 kHz
999.9 kHz 10 kHz No especificada
Tensión de entrada: 1 V rms ~ 20 V rms
Ciclo de trabajo
Rango Resolución Exactitud
5% ~ 99% 0.1%
1 Hz ~ 10kHz: ± (2% + 5)
>10 kHz: No especificada
Tensión de entrada: 3 Vp-p ~ 10 Vp-p
Protección de sobrecarga: 600 V CC/CA rms
Resistencia
Rango Resolución Exactitud
400Ω 0,1 Ω ± (1,0% + 5)
4kΩ 0,001 kΩ
± (1,0% + 3)
40kΩ 0,01 kΩ
400kΩ 0,1 kΩ
4MΩ 0,001 MΩ
40MΩ 0,01 MΩ ± (1,8% + 5)
Capacitancia
Rango Resolución Exactitud
40nF 0,01 nF ± (4%+20) (REL)
400nF 0,1 nF ± (3%+5) (REL)
4µF 0,001 µF
± (4% + 5)
40µF 0,01 µF
100µF 0,1 µF ± (8% + 5)
Para los rangos < 400nF, utilice el modo relativo (REL) para sustraer
la capacitancia parásita de los cables de prueba y del medidor.
Para el rango de 100µF, espere aproximadamente 30 segundos para
que se estabilice la lectura.
61


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Stanley FMHT0-77421 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Stanley FMHT0-77421 in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Spanish as an attachment in your email.

The manual is 17,25 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info