17.10 SENSITIVITY MENU
All settings in the Sensitivity menu are related to the selected Fish Finder transmit frequency
(50 or 200kHz).
Figure 17.10 - Sensitivity menu
17.10.0 Gain
Allows you to control the Sensitivity of the unit’s receiver from 0 to 100%. To see more detail, increase
the receiver Sensitivity by selecting a higher Gain percentage. If there is too much detail or if the
screen is cluttered, lowering the Sensitivity may increase the clarity of the display.
NOTE
When the Gain Mode option is set to Auto, the receivers Gain cannot be changed.
When the Gain Mode option is set to Manual, the Gain can be manually adjusted. When switching
from Automatic to Manual Mode, the Gain + Offset value is copied into the Manual Gain setting of
the receiver.
17.10.1 STC (Sensitivity Time Control)
The STC function attenuates echos from surface down to the specified STC depth by
changing the sensitivity of the receiver, decreasing it near the surface and gradually
increasing it as the depth increases.
STC impacts bottom finding so can be particularly useful i.e. to better track a rock sea
bottom distinguishing it from the mud in suspension over it for example when close to rivers
outlet to the sea (consider to use at same time also Dual Frequency mode and White Line
for an easier identification of real sea bottom), as well as to solve issues in false bottom
detection when in presense of significant surface clutter.
Its default value is SHORT for the 200 kHz frequency and MID for the 50 KHz frequency.
Such values are good in most conditions. However when navigating in very shallow waters
it may be necessary to switch it to OFF, while in very deep waters with a lot of Surface Clutter
it may be better to increase it to MID or LONG.
NOTE
In some situations it may be necessary to adjust the STC so the sounder can read through the
surface noise and show the bottom. One indication that the STC needs to be changed is when the
display intermittently changes the depth from the correct depth to a very shallow depth.
Figure 17.10.1 - STC - Surface Clutter
138


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Standard Horizon CPF300i at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Standard Horizon CPF300i in the language / languages: English as an attachment in your email.

The manual is 3,86 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info