807160
10
Zoom out
Zoom in
Previous page
1/76
Next page
perature. Pushing the «» button reduces the target temperature. The
setting is saved if no change occurs on the control panel for selection of
temperature for three seconds. The current room temperature is subse-
quently shown on the display.
Info: The appliance switches off the heating element when the target
temperature is reached and the temperature indicator flashes on the
display. The ventilator remains switched on for 30 seconds at the low-
est level to cool down the heating element. The current temperature is
then measured approx. every 30 minutes (the fan runs for 1 minute at the
lowest level). The appliance switches on again if the room temperature
recorded drops below the set target temperature.
5. Cooling mode: the heating element switches off if the temperature is set
to 0 °C and the ventilator blows cool air out of the appliance. The LED
light (7) changes from red to blue. There is no temperature shown on the
display in cooling mode.
6. The heat output level can be changed over the left control panel (9)
«Power Level». The display flashes during the input process. Typing «
increases the output level. Typing «» reduces the output level. The set-
ting is saved if no change occurs on the control panel for selection of heat
output level for three seconds. The current room temperature is subse-
quently shown on the display.
7. Auto mode is activated by pressing the «Auto Mode» button (10). «Auto
Mode» is shown in the display. The preset target temperature of 22 °C
can be changed using the right-hand control panel for selection of tem-
perature (8). The heat output level is selected automatically in auto mode
- depending on the room temperature. The smaller the difference be-
tween the room temperature and the target temperature, the smaller the
heat output level selected. We refer to this as «Adaptive HeatTM» technol-
ogy and we have filed for an international patent. This allows Anna big to
make sure that the target temperature is reached, quickly and efficiently,
and maintained. Anna big thus prevents a sharp temperature drop and
prevents the appliance from being constantly switched on and off. Auto
mode is deactivated if the heat output level is changed manually (9).
Info: The appliance switches off the heating element when the target
temperature is reached and the temperature indicator flashes on the
display.
8. Switch off the appliance by pressing the On/Off button (6). The ventilator
remains switched on for 30 seconds at the lowest level to cool down the
heating element. The appliance saves the temperature input and the heat
output level even if the appliance is switched off.
9. Protection against overheating: the appliance is equipped with overheat-
ing protection which switches off the appliance in the event of a techni-
cal fault or improper use (the ventilator continues to run for some time at
the lowest level to cool down the appliance). Should this occur, rectify the
fault or cease the improper use (e.g. 50 cm space around the appliance, do
not cover the appliance, set the appliance up in an upright position). Once
the appliance has cooled down it can be put back into service.
10. The temperature indicator can be changed from Celsius to Fahrenheit and
vice versa by pressing the «Auto Mode» button (10) for five seconds.
11. In the first few hours after putting Anna big into operation there might be an
unpleasant smell. This smell will dissipate and it is nothing to worry about.
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Stadler Form Anna Big at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Stadler Form Anna Big in the language / languages: English, German, Dutch, Danish, French, Italian, Swedish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 1.99 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info