1. General
This manual is meant to provide the user with the
essential information required for installing, using and
servicing the pumps.
A fault-finding chart indicating possible cause and
remedy for every problem which might occur, is
included.
2. Technical characteristics and materials
The electric pumps are the centrifugal, radial, close-
coupled type, with single impeller.
Cast iron pump-body and support, stainless steel
threaded counter flanges.
Stainless steel motor shaft; bronze impeller for the
high head range; cast iron impeller for the low head
range.
Mechanical seal housing standardized to DIN 24960.
The mechanical seal is lubricated by the pumped
liquid.
All the electric pumps come fitted with threaded
counter-flanges.
Amply dimensioned ball-bearings pre-packed with
special grease for life.
2 pole electric motors of enclosed type, IP 55, with
external ventilation; insulated according to Class F.
Standard supply voltages:
50 Hz=230/400 V
up to 7,5 kW - 400/700 V
for higher power ratings.
60 Hz=230/400 V for all powers.
Standard voltage V 230 - 50 Hz.
On request, special voltages available.
In the standard versions the electric pumps are
suitable for fluid temperatures up to 90°C.
Maximum working pressure: 10 Bar.
3. Applications
The electric pumps are suitable for application in the
civil, agricultural and industrial fields, to pump chemi-
cally or mechanically non aggressive liquids. Any
suspended solid particles should not exceed 2% by
weight. The following are but a few typical applications:
water supply systems, irrigation schemes, pressure
tank feed, pressure boosting, air conditioning system,
heating systems.
4. Installation
The pumps may also be located outdoor, provided
they are suitable protected by a roofing; they can also
be installed inclined or vertically.
Warning:
For operation in hot damp environments, the pump
should not be installed orientated to different directions
than normal, to avoid condensation water building up
inside the motor.
Avoid vertical position with motor facing down ward
(see installation diagram - Fig. 5).
Being generously dimensioned, these pumps can be
supported by the pipework of the system to which
they are applied, even though it would be preferable
- where possible - to secure them firmly to a bedplated
by means of four holding-down bolts fitted through
the holes provided in the pump feet. Firm mounting
will aid to damp down vibrations, if any.
A satisfactory installation should conform to the
following indications:
The suction pipe, the inside diameter of which should
never be smaller than the pump inlet, should be
dimensioned consistently with the system and the
pumped liquid. Bear in mind that the maximum theo-
retical suction lift not only is reduced by the NPSHr
required by the pump, which is a peculier characteristic
of the pump itself, but is also reduced by the height
above sea level of the installation and the friction
losses occurring in the suction line.
Therefore, in order to avoid cavitation, which would
generate noise, performance drop and vibrations that
might exert undue mechanicals stress on the pump,
the following relation should always be observed:
hp + hz ≥ (NPSHr + 0.5) + hf + hpv
where:
hp
is the absolute pressure acting on the free surface of
the liquid in the suction reservoir, expressed in meters
of liquid. hp is the quotient between the barometric
pressure and the specific weight of the liquid.
hz
is the difference in level between the pump axis and
the free surface of the liquid in the suction reservoir
expressed in metres. hz is negative when the liquid
level is below the pump axis.
hf
is the head loss occurring within the suction line and
the fittings fitted to it, such as connectors, foot valve,
sluice valves, bens, etc.
2
INSTRUCTIONS FOR THE INSTALLATION AND USE OF ELECTROPUMPS
fig. 1 - Pump installation
The head losses can be read from the diagram shown
in our catalogue, and in order to reduce them to a
minimum - mainly where suction is remarkable (over
4-5 metres) or when operating at the highest flow
rates - it is advisable to use a section pipe larger than
the pump inlet. In all cases it is advisable that the
pump be installed as close as possible to the source
of the pumped liquid.
3
hpv
is the vapour pressure of the liquid at the operating
temperature, expressed in metres of liquid. hpv is
the quotient between the vapour pressure and the
specific weight of the liquid.
0.5
is a margin of safety.
From the above relation it can be gathered that the
maximum permissible suction lift in an installation
depends on the value of the atmospheric pressure
(i.e. the height above sea level of the installation) and
the liquid temperature. To facilitate the user’s task,
tables are provided which - the datum being water
at 4°C and at sea level - indicate the decrease in the
hydraulic pressure head as a function of the height
above sea level and the suction losses as a function
of the temperature.
Height above
sea level (m)
Suction losses
in m.
500 0,55
1000 1,1
1500 1,65
2000 2,2
2500
3000 3,3
2,75
21,5
Water
temperature (°C)
Suction
loss (m)
20 0,2
40 0,7
60 2,0
80 5,0
90 7,4
110 15,4
120
Wrong
Reducer and negative inclination
generate air locks
Scanty immersion=vortex
and whirlpools
• Sharp bends
• Narrow piping
Right
• Eccentric reducer
• Positive inclination
• Good immersion
• Ample bends
Suction pipe dia.≥ pump inlet
Check valve at the delivery
B
A
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Speroni CS at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Speroni CS in the language / languages: English, German, French, Italian, Spanish as an attachment in your email.

The manual is 13,65 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info