CHAPTER 3 - INSTALLATION
DANGER
The installation operations must be performed by expert,
qualied personnel
Use specic guards and equipment as per safety
standards
Fully comply with safety and acci dent prevention
standards in force.
DANGER
Electric shock risk
Warns that the failure to follow the directions given may
cause electric shock.
3.1 HYDRAULIC CONNECTION
The system can be used with a direct connection to the aqueduct or suction from a first tank.
DANGER
For connection to the aqueduct, pay full attention to local
standards in force.
Check the sum of the intake pressure and the maximum
pressure of the motor pump do not exceed the maximum
values allowed by the system.
CMX
series electropumps are not self-priming. It is advis able to install it under the level of the water. If
the electropump is to be installed above the water le vel then a suction pipe should be used with a
diameter equal to that of the suction duct for electropump. If the height betw een the pump axis and
the minimum basin level is over 4 meters use a tube with a larger diamet er. The suction line should
be perfectly airtight. No elbows and/or slopes should be present to prevent the format ion of air locks
that could affect the electropump efficiency. A standing valve with filter should be fitted at about half a
metre below the fluid that has to be pumped on one end of the line.
Load losses can be reduced using delivery piping with a di ameter equivalent or greater than the
electropump mouth. It is advisable to install a check valve direct ly on the delivery line to prevent the
electropump being damaged by “water hammer”.
A cut-off valve should also be installed downstream from the check valve, to facilitate servicing ope-
rations.
Piping should be fitted so that vibrations, when existi ng, tension and weight do not affect the pump.
Piping should be routed along the shortest and straighter track, avoiding an ex cessive number of
bends.
3.2 PRIMING
DANGER
Never start the machine if it is not completely lled with
water.
3.2.1 NEGATIVE SUCTION HEAD
For negative suction head filling of a machine, proceed as follows:
• Close the gate on the delivery tubing
• Open the priming plug
• Slowly open the gate on the suction tubing
• When the liquid flows out of the prim ing plug continuously, tighten the plug.
• Fully open the gate on the de livery and suction tubing
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Speroni CMX at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Speroni CMX in the language / languages: English, French, Italian as an attachment in your email.

The manual is 7,31 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info