GB 40
Bleed it daily until there is no air during the subsequent weeks.
If noises (air bubbles) can be heard in the heat exchanger.
When the pressure in the domestic water supply has been adjusted.
6.4 CLEANING THE WATER HEAT EXCHANGER SENSO M
H2O / PIKO H2O
Cleaning the water heat exchanger is essential. With regular and proper mainte-
nance, the stove can deliver its full potential. Cleaning must always be executed
in cooled-down status!
The water heat exchanger should be cleaned once daily, or each time the
ash drawer is emptied, once it has cooled down. Regular operation of the
cleaning system prevents the system from seizing.
If after the first cleaning operations, it is noticeable that little to no deposits were
removed, this means that you can extend the cleaning interval for your operating
conditions. If, on the other hand, heavy deposits are found during cleaning, then
cleaning must be carried out more frequently and the cleaning interval must be
shortened.
If the cleaning mechanism can only be operated with increased force after
prolonged operation, this is an indication of disproportionate contamination of
the water heat exchanger. In this case, please check the moisture content of
the fuel (< 20 %) and make sure that the heating integration works properly
(min return temperature > 62°C). If you are not sure that these conditions have
been complied with, please contact your installer for heating installations. When
inserting the operating handle, ensure that it does not hit the painted edges!
The soot discharged by cleaning automatically falls onto the baffle plate in the
combustion chamber and should be cleaned off from there at least 2 times per
season.
SENSO M H2O
Because the water heat exchanger cools down the flue gases of the Senso
6.3.2 MAINTENANCE OF THE WATER HEAT
EXCHANGER SENSO M H2O / PIKO H2O
Maintenance of Senso M H2O / Piko H2O is essential The Senso M H2O / Piko
H2O can only function at full efficiency if it is regularly and properly serviced.
The technical heating inspection and checking of all safety devices (thermal
discharge safety device, safety valve, etc.) and of the other components, such
as the pump thermostat, is required yearly before the heating season. The
inspection must be carried out by a specialist company. We recommend that you
conclude a maintenance contract with your specialised company. The annual
safety inspection is carried out reliably before the heating season. All annual
safety inspections must be documented!
6.3.3 VENTING THE WATER HEAT EXCHANGER SENSO M
H2O / PIKO H2O
SENSO M H2O
The vent is located behind the upper cladding door. The bleeder can be opened
with the supplied bleed key.
Bleeding the system:
Before commissioning and again after the first operating days.
If noises (air bubbles) can be heard in the heat exchanger.
When the pressure in the domestic water supply has been adjusted
Piko H2O
The bleeder is located under the ash drawer in the lower compartment. The
bleeder can be opened with the supplied bleed key. There should be an appro-
priate collecting vessel or a large cloth kept ready for collecting the escaping
water. A small tube can also be inserted on the bleeder. When opening the valve,
water initially emerges from the bleed line and then air afer a few seconds. After
the air has escaped, leave the valve fully open for a further five seconds.
Bleeding the system:
Before and during initial commissioning
40


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Spartherm Senso S at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Spartherm Senso S in the language / languages: English as an attachment in your email.

The manual is 3.7 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Spartherm Senso S

Spartherm Senso S User Manual - German - 52 pages

Spartherm Senso S User Manual - Dutch - 53 pages

Spartherm Senso S User Manual - Dutch - 44 pages

Spartherm Senso S User Manual - French - 53 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info