744242
21
Zoom out
Zoom in
Previous page
1/53
Next page
GB
GB 21
2.3.7.2 BASIC REQUIREMENTS FOR INSTALLATION OF H2O
The Senso M H2O / Piko H2O must only be mounted in thermostatically pro-
tected systems in accordance with DIN 4751 or DIN EN 12828. All lines to the
heating network must always be designed so that they can be detached (e.g.
as threaded fitting).
Before the stove is placed in service, it must be filled and ventilated on the
heating side (heating network) and water side (thermal discharge safety
device, safety heat exchanger). After the filling process, check all hydraulic
connections for leaks.
Operation without a water-side connection results in irreparable dam-
age and invalidates any warranty claims!
In the direct vicinity of the Senso M H2O / Piko H2O, a type-tested safety valve
(identification letter H) with an activation overpressure of max. 3.0 bar must
be mounted in the flow line. A shut-off possibility must not be integrated in the
system between the safety valve and the Senso M H2O / Piko H2O. This could
render the safety device inoperable. Moreover, all necessary safety devices
must be integrated in the entire system in such a manner that safe operation is
ensured. A separate safety valve must also be installed, if such a safety valve
is installed at a different point in the entire system (comply with TRD 721!).
When installing, the instructions in the installation and operating manuals of
the installed heating-related components/additive components must always
be complied with!
2.3.7.3 THERMAL DISCHARGE SAFETY DEVICE (TAS)
Since the heating of the Senso M H2O / Piko H2O is not automatic and can be
quickly switched off, according to DIN 4751 – Part 2 and DIN EN 12828, the
stoves are equipped with a thermal discharge safety device. For this, a safety
device (safety heat exchanger) is integrated in the Senso M H2O / Piko H2O to
137
232
292
135
218
232
292
500
500
383
218
A = inlet of thermal discharge safety
device ½" IG
B = discharge of thermal discharge safety
device ½" IG
C = return ¾" IG
D = flow ¾" IG
E = bleeder 3/8"
Connections Piko H2O (view from below)
104
138
170
234
273
295
334
A = return ¾" IG
B = inlet of thermal
discharge safety device ½" IG
C = flow ¾" IG
D = discharge of thermal
discharge safety device
½" IG
Connections Senso M H2O (back view)
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Spartherm Senso L at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Spartherm Senso L in the language / languages: English as an attachment in your email.

The manual is 3.7 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Spartherm Senso L

Spartherm Senso L User Manual - German - 44 pages

Spartherm Senso L User Manual - Dutch - 53 pages

Spartherm Senso L User Manual - Dutch - 44 pages

Spartherm Senso L User Manual - French - 57 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info