744251
13
Zoom out
Zoom in
Previous page
1/53
Next page
GB
GB 13
Note on Redoro S and M
The separate combustion air connection can be connected from below and
comes out to the back or to the side. The connecting piece is preassembled
and the cladding must be removed accordingly.
1. Open the stove door and remove the four countersunk screws at the
bottom.
2. Remove the lower cover part by grabbing it at the side and pulling it
towards to the front.
3. Connect the connecting pipe shown here in blue with the receiving
unit for the SVS connecting piece.
4. After connecting the combustion air connection, push the lower cover
part onto the receiving unit as shown in green here and fix it with the
four countersunk screws.
2.3.2.3 ROOM-AIR-INDEPENDENT
The RLU stoves have been developed for use with residential ventilation systems
for a vacuum range of up to 8 Pa in the installation area and can be operated
without additional safety equipment. The combustion air must be supplied in
airtight lines from the outside or via an LAS system to the device for room-air-in-
dependent operation without fail. To do this, the combustion air duct must be
permanently sealed to the combustion air neck (connection type back/side or
bottom) of the stove.
When connecting the RLU stove to a combustion air line, the TROL instruc-
tions (technical rules), the DIN 18896, etc. must be observed and applied.
In particular, ensure that the dimensions are adequate!
Country-specific and local fire safety regulations must be observed! Make
sure that the pipes are always airtight.
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Spartherm Piko S at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Spartherm Piko S in the language / languages: English as an attachment in your email.

The manual is 3.7 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Spartherm Piko S

Spartherm Piko S User Manual - German - 52 pages

Spartherm Piko S User Manual - Dutch - 53 pages

Spartherm Piko S User Manual - Dutch - 44 pages

Spartherm Piko S User Manual - French - 53 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info