810451
23
Zoom out
Zoom in
Previous page
1/44
Next page
GB
GB 23
For access to the water-side connections an inspection opening can be
opened in the rear wall or the side wall. To do this, the combustion chamber
lining (side walls, rear wall, ash grate, ash pan and combustion chamber
floor) must be dismounted.
After the inspection the closure plate must be remounted and the combus-
tion chamber lining must be installed. Accessibility to the flow connection
and to the front-side ventilation must be enabled via an opening in the
heating chamber wall.
1Flow connection
2Temperature sensor for thermal discharge safety device
3Temperature sensor – thermostatic switch
4Ventilation
5"Discharge" – safety heat exchanger
6"Inlet" – safety heat exchanger
7Return connection
8Inspection opening
9Connection for optional safety valve
Note for all fireplace inserts:
Operation without combustion chamber lining is not permitted!
Varia FD/FDh H2O
Varia 1VX/1VXh H2O
Abb. 2h
4
2
3
1
5
6
7
35
117
1282
80
218
23


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Spartherm Mini H2O at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Spartherm Mini H2O in the language / languages: English as an attachment in your email.

The manual is 4.01 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Spartherm Mini H2O

Spartherm Mini H2O User Manual - German - 44 pages

Spartherm Mini H2O User Manual - Dutch - 44 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info