810310
22
Zoom out
Zoom in
Previous page
1/35
Next page
- 43 -
Mögliche Variante für die Einbindung des Mini Z1 H2O, Mini Z1 H2O XL
und Mini Z1h H2O XL in eine Heizungsanlage (Abb. 5a).
A Temperaturfühler für thermische Ablaufsicherung ½““
B Temperaturfühler für Thermostatschalter ½“
C Vorlauf ¾“
D Sicherheitsventil 3bar
E Entlüftung
F Thermostatschalter Pumpe (z.B. Fa. JUMBO, heat THERM)
G Rücklaufanhebung
H Rücklaufanhebungsarmatur (z.B. Fa. ESBE ; Typ LTC 141)
I Umwälzpumpe
J Befüll- und Entleerungsarmatur
K Ausgleichsbehälter
LSicherheitsarmatur für thermische Ablaufsicherung (z.B. Fa. SYR,
3065)
M Ablauf
N Rücklauf ¾“
O „Ablauf“ thermische Ablaufsicherung ½“
P „Zulauf“ thermische Ablaufsicherung ½“
Q Entlüftung 3/8“
R Anschluss Heizungssystem
S Pufferspeicher
- 44 -
Abb. 5b
Varia 1V H2O
Varia 1Vh H2O
22


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Spartherm H2O Mini at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Spartherm H2O Mini in the language / languages: German as an attachment in your email.

The manual is 7.74 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info