2.3 INSTALLATION SITE
During set-up and installation of the ebios-fire, ensure that the equipment
is not located immediately beside major heat sources (radiators, chimney
ovens etc.) or in installation spaces with high temperature loads (e.g. sau-
nas). Outside heating of the ethanol fireplace when it is not in operation can
cause the fuel in the tank to be forced out through the burner channel and
then to collect in the safety tray. In such cases, before lighting the ebios-
fire, remove the burner and empty the safety tray.
Your ebios-fire must not be set up:
In stairways except in residential buildings with two or fewer flats.
In hallways with general access.
In garages
Outside
In rooms containing readily flammable or explosive substances or where
mixtures are processed, stored or manufactured in such quantities that
combustion or explosion could constitute a hazard.
In insufficiently ventilated rooms.
In publicly accessible areas without supervision.
In areas not protected against lateral ventilation.
On tables, furniture items, wall-mounted shelving units etc.
2.4 SET-UP AND ASSEMBLY
The ebios-fire Quadra Inside is a ready-to-use item of equipment for instal-
lation in the top panel of a customized item of furniture (combustible materi-
als) or in an individually crafted, open fireplace (not combustible materials).
In the case of individually crafted fireplaces with the Quadra Inside, no
exhaust ducting is required.
The ebios-fire furniture item, whether free-standing or wall-mounted must
be set up horizontally and secured to prevent tilting.
The fireplace inserts may only be installed in recesses with a sufficient
load bearing capacity. If the load bearing capacity is not sufficient, suitable
measures must be taken (e.g., plate for load distribution) to remedy this.
NO modifications may be made to the design of the ebios fireplace insert.
2.5 GENERAL INSTRUCTIONS FOR INSTALLATION IN
TAILOR-MADE FIREPLACE CLADDING
When designing tailor-made items of furniture, all the minimum dis-
tances and installation dimensions must be observed.
The installation recess must have a sufficient load bearing capacity
The ebios fireplace insert must be aligned horizontally
The furniture items must always be secure to the wall or to the floor
respectively and secured to prevent accidental dislodgement, e.g. after a
collision impact and/or from being lifted up. To accomplish this, choose
appropriate fastening material.
Installation in individually create fireplace cladding wood is permitted
only up to a body length of 1000mm. A lining of the insertion niche with
40mm calcium silicate boards is always needed.
All inlet air apertures and rear ventilation points must be kept clear and
must not be obstructed because a heat build-up might otherwise occur.
Danger of fire!
There must be an air gap of 10 mm around the body and be-tween the
panel and mounting wall. An air gap of 20 mm must be provided to the
rear (see the installation diagram fig. 1).
The cross-section of the air intake opening for supplying air to and
cooling the burner is based on the burner type and must be positioned
in the direct vicinity of the body. Please refer to the relevant burner
instruction manual (automatic or wick burner) and the instructions under
Point 2.5.1.
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Spartherm Ebios Fire Kensington at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Spartherm Ebios Fire Kensington in the language / languages: English as an attachment in your email.

The manual is 3.6 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Spartherm Ebios Fire Kensington

Spartherm Ebios Fire Kensington Usermanual and installation guide - German - 16 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info