GB 5
For homes in Germany the general rule is:
Storage in the basement: not more than 20 litres
Storage in the living-room: not more than 5 litres
(Source: Hazardous Substances Information Data Sheet published by the Association of the Raw Materials
and Chemical Industry; also Technical Rules for Flammable Fluids 20)
1.1 SCOPE OF SUPPLY
ebios-fire with the following features:
Tower housing (base) with stainless steel fire tray, top glass panel, three
glass supports and glass tubes
2 x canister closing systems with hose connection
Radio remote control
Charger for integral battery
Installation and Operating Manual
2. INSTALLATION INSTRUCTIONS
Please carefully read and note the following instructions. Remember that
bioethanol is a liquid fuel that can generate high temperatures when burned
and which is itself highly flammable. You should also bear in mind that the
brightness of the flame can dim to a level at which the flame is no longer
clearly visible. Please make children and other people in the home aware of
this. Failing to follow the installation and operating instructions can result
in dangerous situations and the possibility of explosive ignition of the fuel.
Correct installation and proper handling are essential to ensure safe, reli-
able operation of your fire.
The unit is not self-supporting. It must be installed as per the instructions,
ensuring it is horizontal. Never move the burner when the unit is operating.
The unit must be installed in such a way that it cannot be knocked over or
tilted.
2.1 FUNCTIONAL DESCRIPTION
Once the operating voltage is applied to the burner (via battery or charger),
pressing the switch behind the flap door in the base will switch it to opera-
tional mode. Ignition is then started via the remote control. During this
phase the pump operates continuously, whereas ignition takes place at
intervals. This fills the fire tray with fuel, which then ignites.
Ignition stops automatically as soon as the ethanol level is sufficient for
operation. The integral pumps feed fuel into the tray until the level reaches
the level sensor. At that point the pumps switch off.
The level falls as the fuel burns. When the fuel is no longer in contact with
the level sensor, the pumps start up again and continue pumping until the
level reaches the sensor again.
Only one pump is in operation at any one time. That helps keep the power
consumption low.
The burner is supplied with two sets of fuel lines for operation with two
canisters. First of all, pump 1 empties canister 1. Then the system switches
over to pump 2 and canister 2. Always make sure the burner is switched off
before exchanging an empty canister for a full one.
It is also possible to operate the unit with just one canister. This can be
done by operating the burner with only one set of fuel lines and one canister
(detach the filling adapter and quick-action coupling from the line).
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Spartherm Ebios fire - Tower at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Spartherm Ebios fire - Tower in the language / languages: English as an attachment in your email.

The manual is 2.89 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Spartherm Ebios fire - Tower

Spartherm Ebios fire - Tower Usermanual and installation guide - German - 20 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info