2.1 TECHNICAL DATA
ebios-fire
Fuel type: Bio-Ethanol
(Ethanol content 96%)
Fill quantiy: max. 2,6 l
Fuel consumption: 0,5 l/h
Burning time: ca. 5 h*
Temperature in the tank: < 65°C
Weight of burners (empty) incl. cover plate: 5,3 kg
Minimum volume per burner: ** 84m³ 167m³ 418m³
Air exchange at air exchange rate: ** 1 0,5 0,2
Corresponding room size at room height 2.5m ** 34m2 67m2 167m2
The following are rough air exchange estimates 1):
Air exchange [1/h] Note
0…0,5 Windows and doors closed
0,3…1,5 Window tilted, no blinds
5…10 Window half open
1) Recknagel, Sprenger, Schrameck: Heizung+Klimatechnik, Oldenbourg Verlag
** Please note that the brightness of the flame may diminish until the flame
is no longer clearly visible. Point this out to your children and other per-
sons in the household.
** This information refers only to the ebios-fire air demand for combus-
tion. Any further air consuming devices in the room must be considered
separately.
Overview of model illustrations:
Model Elipse
Placement Floor
Number of burners 1
Width mm 960
Depth mm 235
Height mm 220
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Spartherm Ebios Fire - Solitar at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Spartherm Ebios Fire - Solitar in the language / languages: English as an attachment in your email.

The manual is 0.83 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info