695789
21
Zoom out
Zoom in
Previous page
1/36
Next page
GB
GB 21
3.7.1 MINIMUM DIMENSIONS FOR FIREPLACES CRE-
ATED BY CRAFTSMEN
3.7.1.1 QUADRA INSIDE I SL
The minimum width of fireplace measures 750 mm.
The height of the fireplace insert measures at least 350 mm.
The depth of the fireplace insert is defined as 400 mm.
The distance from front edge of combustion chamber to housing frame
is defined as 50 mm.
The cutaway in the base of the combustion chamber (support panel of
the Quadra Inside I) measures 689 x 224 mm.
The minimum distance between housing and housing area base meas-
ures 70 mm.
The minimum width of combustion chamber measures 750 mm.
The minimum depth of housing area measures 360 mm.
The minimum free cross section for the additional air aperture on
the housing area measures 200 cm².
The combustion chamber is made of vermiculite slabs or ob calcium
silicate slabs with a material thickness of at least 40 mm. These building
materials must be approved by the German Institute of Building Tech-
nology in Berlin (DIBt), to verify their suitability for use as combustion
chamber lining.
The thermal insulation to be used comprises mats, slabs or pipe sections
of silica-based insulation material (stone or slag and ceramic fibres) of
material class A1 as per DIN 4102, part 1 with an upper application
limit temperature of at least 700°C when measured as per DIN 52271
and a rated gross density of 80 kg/m³. When using insulating materials
of this type, ensure they are provided with an AGI-Q 132 code number
(details of thermal insulation thickness (Fig. 28) refers to mineral wool,
as defined in AGI Q 132).
Ensure that additional air can flow into the housing area without obstruc-
tion. Free cross section for additional air is 200 cm². For this, provide
appropriate additional air apertures.
The Quadra Inside must be bolted to the support panel using 6 appropri-
ate screws.
1Firebox 5Vermiculite or calcium silicate slab
t 40 mm
2Housing area 6Mineral wool insulation
(in acc. with AGI-Q 132) t 60 mm
3Quadra Inside 7External cladding
4Additional air aperture
Free cross section, min. 200 cm²
min.
min.
min.
Fig. 28 Minimum distances from fire area
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Spartherm Ebios Fire - Quadra Inside I SL at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Spartherm Ebios Fire - Quadra Inside I SL in the language / languages: English as an attachment in your email.

The manual is 4.86 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Spartherm Ebios Fire - Quadra Inside I SL

Spartherm Ebios Fire - Quadra Inside I SL Usermanual and installation guide - German - 36 pages

Spartherm Ebios Fire - Quadra Inside I SL Usermanual and installation guide - Dutch - 44 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info