695788
8
Zoom out
Zoom in
Previous page
1/28
Next page
GB 8
Please note that the ethanol container must be located under the burner
(maximum height difference of 4 metres, minimum height difference
between top edge of burner and top edge of canister opening to be 0.5
metres for every 4 metres), otherwise there is a risk, in the event of a leak,
of the uncontrolled escape of ethanol. For this purpose, keep the hoses as
short as possible (maximum hose length 8 metres) and protect the hoses
against contact with sharp, pointed, hot or abrasive objects.
The storage location for the ethanol canisters, assuming that the ebios-fire
5-litre containers are being used, should have minimum dimensions of 350
mm x 180 mm x 240 mm (H x W x D). Furthermore, the location must be
designed to prevent any accumulation of combustible gases, where escap-
ing ethanol can be caught and where the propagation of fire is prevented.
Please also ensure that the drain hose from the ethanol burner to the canis-
ter is not on a gradient, and also that it is not U-shaped. Failure to observe
this can prevent any reasonable drainage from taking place in the event of
an overflow.
Important installation notices:
Ensure that the appliance is absolutely balanced. IMPORTANT!
Any failure to observe this point can cause the burner channel to
overflow.
The Allen screws in the corners of the installation frame are there to
level the entire appliance, not to secure it in its frame.
2.5 INSTALLATION / ASSEMBLY
The ebios-fire Quadra Inside Automatic I SL and II SL are ready-to-use
appliances for installation in the top plate of an individually created item
of furniture (combustible materials) or in a bespoke open fireplace (non-
combustible materials).
The ebios-fire furniture item, whether free-standing or wall-mounted, must
be aligned horizontally and secured to prevent it from toppling over. Secure
wall-mounted models to the wall and floor-mounted models to either the
wall or the floor. Please note the safety distances. (Fig. 10 Radiation range).
Rear ventilation must not be closed. Place the burner in the installation
frame provided in the Quadra Inside Automatic I SL or II SL.
Floor-mounted furniture may only be set up on floors with sufficient load-
bearing capacity. If the load bearing capacity is not sufficient, suitable
measures must be taken (e.g. a panel for load distribution) to remedy this.
Use suitable fastening material (wall plugs, screws etc.) when securing to
the wall.
Without exception NO modifications are permitted to the design of the
Quadra Inside Automatic I SL or II SL.
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Spartherm Ebios Fire - Quadra Inside Automatic I SL at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Spartherm Ebios Fire - Quadra Inside Automatic I SL in the language / languages: English as an attachment in your email.

The manual is 1.98 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Spartherm Ebios Fire - Quadra Inside Automatic I SL

Spartherm Ebios Fire - Quadra Inside Automatic I SL Usermanual and installation guide - German - 28 pages

Spartherm Ebios Fire - Quadra Inside Automatic I SL Usermanual and installation guide - Dutch - 24 pages

Spartherm Ebios Fire - Quadra Inside Automatic I SL Usermanual and installation guide - Dutch - 44 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info