2.5 INSTALLATION SITE
When setting up/installing the ebios-fire ensure that the device is not posi-
tioned within the direct radiation area of large heat sources (heaters, stoves
etc.) or in rooms exposed to high temperatures (e.g., saunas). If the ethanol
fireplace is heated up externally when not in use, this can cause fuel in the
tank to be expelled over the burner channel and accumulate in the safety
tray. In such cases, the burner is to be removed and the tray emptied before
the ebios-fire is lit.
Your ebios-fire must not be installed in:
In stairways, unless they are in residential buildings with two or fewer
flats.
In hallways with general access.
In garages.
In rooms in which highly combustible or potentially explosive substances
or mixtures are processed, stored or manufactured in quantities that
would be hazardous in the event of ignition or explosion
In insufficiently ventilated rooms.
In areas accessible to the public which are not supervised.
In areas which are not protected against transverse ventilation
On tables, pieces of furniture, shelves etc.
2.6 INSTALLATION / ASSEMBLY
The ebios-fire Cambridge 400/600 is a device for wall mounting or for being
installed in the wall, ready for use. A flue gas guiding is not required for the
Cambridge 400/600.
The ebios-fire wall furniture must be fixed aligned horizontally and safely on
the wall. In doing so, observe the applicable safety distances under 2.6.1.
Fire protection / minimum distances. Rear ventilation must not be sealed.
Position the burner in the mounting wall intended for the Cambridge wall
furniture. In doing so, the tank slider must be arranged at the rear left.
Use suitable fastening material (wall plugs, screws etc.) when securing to
the wall.
Basically, NO modifications may be made to the design of the Cambridge
400/600.
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Spartherm Ebios Fire - Cambridge 600 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Spartherm Ebios Fire - Cambridge 600 in the language / languages: English as an attachment in your email.

The manual is 3,1 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Spartherm Ebios Fire - Cambridge 600

Spartherm Ebios Fire - Cambridge 600 Usermanual and installation guide - German - 32 pages

Spartherm Ebios Fire - Cambridge 600 Usermanual and installation guide - Dutch - 20 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info