GB 6
As a rough rule of thumb the following air exchange figures1 )can be stated:
Air change [1/hr] Comments
0…0,5 Windows and doors closed
0,3…1,5 Window tilted, no roller blinds
5…10 Window half open
1) Recknagel, Sprenger, Schrameck: Heizung+Klimatechnik, Oldenbourg Verlag
*** Please note that the luminosity of the flame can decrease to such an
extent that the flame is no longer clearly visible. Make children and
others in the home aware of this.
*** These details relate solely to the combustion air requirements of the
ebios-fire. Should you have additional air-consuming devices installed in
the room, these must be taken into consideration separately.
Graphic illustrations of the model:
Model Cabinet Fire
Placement Installation in a specially manufactured kitchen cabinet
Number of burners 1
Width in mm 595
Depth in mm 326 (without air baffle plate)
Height in mm 595 (without air baffle plate)
Weight in kg approx. 40 kg
2.2 CERAMAT FN BURNER MAT
The CERAMAT FN burner mat (black) included should only be touched when
wearing gloves as there is otherwise a risk of skin irritations. The material
can be easily damaged. As such, the mat should not be folded, bent or
similar.
2.3 BASIC REQUIREMENTS FOR INSTALLATION
All the relevant national and European standards as well as the local regula-
tions (fire protection regulations etc.) must be observed and applied during
installation and operation of the ebios-fire! The list of regulations given
below is not exhaustive
BetrSichV Operational safety ordinance
Vbf Flammable liquids directive
BsV Fire protection directive of the relevant German federal state (Bundesland)
LBO Federal state construction directives
GefStoffV Hazardous substances directive
The ebios-fire may only be set up in rooms and locations where there are
no hazards due to the site, structural conditions and type of use. The floor
area of the installation room must be designed and dimensioned so that the
ebios-fire can be operated properly and as per the intended use.
Only permitted and sufficiently strong transport aids may be used to trans-
port the ebios-fire.
The following points must be noted to ensure safe and problem-free
transport.