BetrSichV German Ordinance on Industrial Safety and Health
Vbf German Ordinance on Flammable Liquids
BsV Fire Regulations of the respective Federal German State
LBO German Federal State Construction Ordinances
GefStoffV German Ordinance on Hazardous Substances
GPSG German Product Safety Act
The ebios-fire may only be set up in rooms and locations where there are
no hazards due to the site, structural conditions and type of use. The floor
area of the installation room must be designed and dimensioned so that the
ebios-fire can be operated properly and as per the intended use.
Only permitted and sufficiently strong transport aids may be used to trans-
port the ebios-fire. The following points must be noted to ensure safe and
problem-free transport.
Transport aids (if necessary), special hand trucks must only be loaded
with the rear of the ebios-fire facing down.
There must be no fuel in the tank during transportation.
DAMAGE DURING TRANSIT should be reported immediately to the supplier.
Protect the cladding and visible elements of the fireplace furniture from
soiling and damage during installation and transportation.
2.5 INSTALLATION LOCATION
When setting up/installing the ebios-fire ensure that the device is not posi-
tioned within the direct radiation area of large heat sources (heaters, stoves
etc.) or in rooms exposed to high temperatures (e.g., saunas). If the ethanol
fireplace is heated up externally when not in use, this can cause fuel in the
tank to be expelled over the burner channel and accumulate in the safety
tray.
In such cases, the burner is to be removed and the tray emptied before the
ebios-fire is lit.
The ebios-fire architecture SL is designed for use both indoors and out-
doors. The following information must be noted if the fireplace is set up
outdoors:
Place the ebios-fire on a free surface and make sure that there are no
flammable materials such as trees, umbrellas etc. which could be blown
over and land in the proximity of the flames. A minimum distance of 30
cm to flammable materials must be guaranteed in all scenarios.
Protect the ebios-fire from moisture and adverse weather conditions.
When not in use, the burner is to be taken out of the concrete base and
stored in a dry place.
The ebios-fire can also be operated as a stand-alone unit without the
concrete base. To ensure that it is safely supported, there are adjustable
feet on the bottom of the burner. Ensure that the unit is the necessary
distance away from nearby components!
Your ebios-fire must not be installed in:
In stairways, unless they are in residential buildings with two or fewer
flats.
In hallways with general access.
In garages
In rooms in which highly combustible or potentially explosive substances
or mixtures are processed, stored or manufactured in quantities that
would be hazardous in the event of ignition or explosion
In insufficiently ventilated rooms.
In areas accessible to the public which are not supervised.
In areas which are not protected against transverse ventilation
On tables, pieces of furniture, shelves etc.
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Spartherm Ebios Fire - Architecture SL at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Spartherm Ebios Fire - Architecture SL in the language / languages: English as an attachment in your email.

The manual is 3.94 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Spartherm Ebios Fire - Architecture SL

Spartherm Ebios Fire - Architecture SL User Manual - Dutch - 20 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info