744258
15
Zoom out
Zoom in
Previous page
1/53
Next page
GB
GB 15
Minimum distances to adjacent components
Depending on the view pane arrangement (see the following graphics) of
your stove and the type of mounting walls, the distances from the table are
to be adhered to.
The following describes
Distance A as the minimum distance of the stove sidewall to the mount-
ing wall
Distance B as the minimum distance of stove back wall to the mounting
wall
Distance C as the area of direct radiant heat in front of the view pane
(n) of the stove
Special note on minimum side distance
Minimum side distance (Fig. 17 (A)) describes the minimum distance from
the stove to the side mounting wall and is valid from the back mounting wall
to the beginning of the area of direct radiant heat (E) of the front panel.
In stoves with curved front pane or a wide area of direct radiant heat, the
minimum wall distance (A) must be adjusted to the extending area of direct
radiant heat.
Determining the area of radiant heat
To layout the area of direct radiant heat of the stove, put a measuring
instrument (ruler or measuring tape) on the surface of the view pane and
determine the centre of the fireplace past the side door pillar (Fig. 18). In
the resulting angle and the distance A1, there must be no combustible or
components to be protected on the sides.
brennbar
(z.B.Sessel)
A1
CMeterstab
Bodenbelag D
Strahlungsbereich
Fig. 18
brennbar
(z.B.Sessel)
E
A
Strahlungsbereich
Bodenbelag D
Fig. 17
Radiant area
Flooring
Combus-
tible
e.g.
(armchair)
Radiant area
Flooring
Combus-
tible
e.g.
(armchair)
Folding rule
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Spartherm Cubo L at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Spartherm Cubo L in the language / languages: English as an attachment in your email.

The manual is 3.7 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Spartherm Cubo L

Spartherm Cubo L User Manual - German - 52 pages

Spartherm Cubo L User Manual - Dutch - 53 pages

Spartherm Cubo L User Manual - Dutch - 44 pages

Spartherm Cubo L User Manual - French - 53 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info